Friedrich ZQ08A10C manual

Page 10

NOTES

Replacement of the refrigeration cycle.

1.When replacing the refrigeration cycle, be sure to Discharge the refrigerant system using a FreonTM recovery System.

If there is no valve to attach the recovery system, install one (such as a WATCO A-1) before venting the FreonTM. Leave the valve in place after servicing the system.

2.After discharging the unit completely, remove the desired component, and unbraze the pinch-off tubes.

3.Solder service valves into the pinch-off tube ports, leaving the valves open.

4.Solder the pinch-off tubes with Service valves.

5.Evacuate as follows.

1)Connect the vacuum pump, as illustrated figure 16A.

2)Start the vacuum pump, slowly open manifold valves A and B with two full turns counterclockwise and leave the valves open. The vacuum pump is now pulling through valves A and B up to valve C by means of the manifold and entire system.

CAUTION

If high vacuum equipment is used, just crack valves A and B for a few minutes, then open slowly with the two full turns counterclockwise. This will keep oil from foaming and being drawn into the vacuum pump.

3)Operate the vacuum pump for 20 to 30 minutes, until 600 microns of vaccum is obtained. Close valves A and B, and observe vacuum gauge for a few minutes. A rise in pressure would indicate a possible leak or moisture remaining in the system. With valves A and B closed, stop the vacuum pump.

4)Remove the hose from the vacuum pump and place it on the charging cylinder. See figure 16B.

Open valve C.

Discharge the line at the manifold connection.

5)The system is now ready for final charging.

6.Recharge as follows :

1)Refrigeration cycle systems are charged from the High-side. If the total charge cannot be put in the High-side, the balance will be put in the suction line through the access valve which you installed as the system was opened.

2)Connect the charging cylinder as shown in figure 16B.

With valve C open, discharge the hose at the manifold connection.

3)Open valve A and allow the proper charge to enter the system. Valve B is still closed.

4)If more charge is required, the high-side will not take it. Close valve A.

5)With the unit running, open valve B and add the balance of the charge.

a.Do not add the liquid refrigerant to the Low- side.

b.Watch the Low-side gauge; allow pressure to rise to 30 lbs.

c.Turn off valve B and allow pressure to drop.

d.Repeat steps b. and c. until the balance of the charge is in the system.

6)When satisfied the unit is operating correctly, use the pinch-off tool with the unit still running and clamp on to the pinch-off tube. Using a tube cutter, cut the pinch-off tube about 2 inches from the pinch-off tool. Use sil-fos solder and solder pinch-off tube closed. Turn off the unit, allow it to set for a while, and then test the leakage of the pinch-off connection.

— 10—

Image 10
Contents Room Air Conditioner Service and Parts Manual ZStarTM Contents PrefaceZQ08A10C SpecificationsModels ItemsControl Locations FeaturesControl only Model Front Grille Disassembly InstructionsMechanical Parts CabinetAIR Guide and Blower AIR Handling PartsFAN and Shroud Compressor Electrical PartsOverload Protector CapacitorRotary Switch Power CordThermostat Evaporator Refrigerating CycleCondenser Capillary TubePage Pulling Vacuum Installation Hardware InstallationSelect the Best Location Wood Pieces Window RequirementsStorm Window Requirements Width Minimum 1 1/238mmPreparing the Unit for Installation Before InstallationInstall the Case in the Window Install the AIR Conditioner in the Case To Reverse the Grille OpeningTroubleshooting Guide Outside DimensionsPiping System Evaporator CoilTroubleshooting Guide Ineffective CoolingFails to Start Name Plate Rating Minimum Maximum Room AIR Conditioner Voltage LimitsComplaint Cause Remedy Complaint Cause Remedy Complaint Cause Remedy Model ZQ08A10C Schematic DiagramCircuit Diagram Description QTYExploded View Replacement Parts List Model ZQ08A10CControl BOX Assy Use Factory Certified Parts
Related manuals
Manual 28 pages 46.28 Kb

ZQ08A10C specifications

The Friedrich ZQ08A10C is an advanced cooling unit designed to meet the needs of residential and commercial environments. This portable air conditioner is especially notable for its efficiency, convenience, and cutting-edge technologies, making it an ideal choice for those seeking reliable temperature control.

One of the main features of the ZQ08A10C is its impressive cooling capacity. With a power rating of 8,000 BTUs, this unit is capable of effectively cooling spaces up to 350 square feet, making it suitable for large rooms, offices, and even some small apartments. The air conditioner operates quietly, allowing users to enjoy a comfortable indoor climate without disruptive noise.

Efficiency is a critical characteristic of the ZQ08A10C. It is equipped with an Energy Efficiency Ratio (EER) that ensures lower energy consumption compared to traditional air conditioning systems, which translates to lower utility bills. This model also utilizes eco-friendly refrigerant, contributing to a reduced environmental impact while maintaining high performance.

The design of the Friedrich ZQ08A10C prioritizes portability and ease of use. Casters allow for effortless movement from one room to another, making it versatile for various settings. Additionally, the unit features a digital thermostat with a remote control, enabling users to set their desired temperature from a distance. The easy-to-read display provides clear information on temperature settings and operational modes.

Technologically, the ZQ08A10C includes multiple fan speeds and a programmable timer, enhancing user control over the cooling experience. The unit also features a dehumidification function, helping to remove excess moisture from the air, which is essential for maintaining comfort in humid environments.

Maintenance is simplified through the inclusion of a washable filter, promoting clean air circulation and extending the lifespan of the unit. Furthermore, the installation process is straightforward, often requiring no additional tools beyond those included in the packaging.

In summary, the Friedrich ZQ08A10C stands out for its robust cooling efficiency, user-friendly features, and portability. Its innovative technologies and durable performance make it a strong contender in the market of portable air conditioning solutions, suitable for a variety of spaces and settings.