Friedrich ZQ08A10C manual Complaint Cause Remedy

Page 22

COMPLAINT

CAUSE

REMEDY

 

 

 

Fan motor noise.

Fan

If cracked, out of balance, or partially missing,

 

 

replace it.

 

 

 

 

Blower

If cracked, out of balance, or partially missing,

 

 

replace it.

 

 

 

 

Loose set screw

Tighten it.

 

 

 

 

Worn bearings

If knocking sounds continue when running or loose,

 

 

replace the motor. If the motor hums or noise

 

 

appears to be internal while running, replace motor.

 

 

 

Compressor will not run,

Voltage

Check voltage. See the limits on the preceding page.

fan motor runs.

 

If not within limits, call an electrician.

 

 

 

 

Wiring

Check the wire connections ; if loose, repair or

 

 

replace the terminal. If the wires are disconnected,

 

 

refer to wiring diagram for identification, and replace

 

 

the wires. Check the wire connections ; if not

 

 

according to the wiring diagram, correct the

 

 

connections.

 

 

 

 

Rotary

Check for continuity, refer to the wiring diagram for

 

 

terminal identification. Replace the switch if the

 

 

circuit is open.

 

 

 

 

Thermostat

Check the position of knob. If not at the coldest

 

 

setting, advance the knob to this setting and restart

 

 

the unit.

 

 

 

 

 

Check the continuity of the thermostat. Replace the

 

 

thermostat if the circuit is open.

 

 

 

 

Capacitor (Discharge

Check the capacitor.

 

capacitor before

Replace if not within ±10% of manufacturer's rating,

 

servicing.)

replace if shorted, open, or damaged.

 

 

 

 

Compressor

Check the compressor for open circuit or graond. If

 

 

open or grounded, replace the compressor.

 

 

 

 

Overload

Check the compressor overload if externally

 

 

mounted.

 

 

Replace if open. (If the compressor temperature is

 

 

high, remove the overload, cool and retest.)

 

 

 

Compressor cycles on

Voltage

Check the voltage. See the limits on the preceding

overload.

 

page. If voltage is not within these limits, call an

 

 

electrician.

 

 

 

 

Overload

Check overload, if externally mounted.

 

 

Replace if open. (If the compressor temperature is

 

 

high, remove the overload, cool, and retest.)

 

 

 

— 22—

Image 22
Contents Room Air Conditioner Service and Parts Manual ZStarTM Contents PrefaceZQ08A10C SpecificationsModels ItemsControl Locations FeaturesControl only Model Front Grille Disassembly InstructionsMechanical Parts CabinetAIR Guide and Blower AIR Handling PartsFAN and Shroud Compressor Electrical PartsOverload Protector CapacitorRotary Switch Power CordThermostat Evaporator Refrigerating CycleCondenser Capillary TubePage Pulling Vacuum Installation Hardware InstallationSelect the Best Location Wood Pieces Window RequirementsStorm Window Requirements Width Minimum 1 1/238mmPreparing the Unit for Installation Before InstallationInstall the Case in the Window Install the AIR Conditioner in the Case To Reverse the Grille OpeningTroubleshooting Guide Outside DimensionsPiping System Evaporator CoilTroubleshooting Guide Ineffective CoolingFails to Start Name Plate Rating Minimum Maximum Room AIR Conditioner Voltage LimitsComplaint Cause Remedy Complaint Cause Remedy Complaint Cause Remedy Model ZQ08A10C Schematic DiagramCircuit Diagram Description QTYExploded View Replacement Parts List Model ZQ08A10CControl BOX Assy Use Factory Certified Parts
Related manuals
Manual 28 pages 46.28 Kb

ZQ08A10C specifications

The Friedrich ZQ08A10C is an advanced cooling unit designed to meet the needs of residential and commercial environments. This portable air conditioner is especially notable for its efficiency, convenience, and cutting-edge technologies, making it an ideal choice for those seeking reliable temperature control.

One of the main features of the ZQ08A10C is its impressive cooling capacity. With a power rating of 8,000 BTUs, this unit is capable of effectively cooling spaces up to 350 square feet, making it suitable for large rooms, offices, and even some small apartments. The air conditioner operates quietly, allowing users to enjoy a comfortable indoor climate without disruptive noise.

Efficiency is a critical characteristic of the ZQ08A10C. It is equipped with an Energy Efficiency Ratio (EER) that ensures lower energy consumption compared to traditional air conditioning systems, which translates to lower utility bills. This model also utilizes eco-friendly refrigerant, contributing to a reduced environmental impact while maintaining high performance.

The design of the Friedrich ZQ08A10C prioritizes portability and ease of use. Casters allow for effortless movement from one room to another, making it versatile for various settings. Additionally, the unit features a digital thermostat with a remote control, enabling users to set their desired temperature from a distance. The easy-to-read display provides clear information on temperature settings and operational modes.

Technologically, the ZQ08A10C includes multiple fan speeds and a programmable timer, enhancing user control over the cooling experience. The unit also features a dehumidification function, helping to remove excess moisture from the air, which is essential for maintaining comfort in humid environments.

Maintenance is simplified through the inclusion of a washable filter, promoting clean air circulation and extending the lifespan of the unit. Furthermore, the installation process is straightforward, often requiring no additional tools beyond those included in the packaging.

In summary, the Friedrich ZQ08A10C stands out for its robust cooling efficiency, user-friendly features, and portability. Its innovative technologies and durable performance make it a strong contender in the market of portable air conditioning solutions, suitable for a variety of spaces and settings.