Makita Initial Start Up Procedure, Extension Cords, Amp Length Rating Cord in Feet, 150

Page 10

Initial Start Up Procedure:

1.Open the air receiver's drain valve.

2.Plug power supply cord into correct power source.

3.Run the compressor for a minimum of twenty (20)

minutes in the no-load condition to seat the piston ring and check valves.

4.Close air receiver drain valve. Your compressor is now ready for use.

Extension Cords

To avoid voltage drop, power loss, and overheating of the motor, use extra air hose instead of an extension cord. Low voltage can cause damage to the motor.

If an extension cord must be used:

·Use only an approved 3-wire extension cord that has a 3- blade grounding plug and a 3- slot receptacle that will accept the plug on the air compressor.

·Make sure the extension cord is in good condition.

Please see the chart below as the MINIMUM requirements:

Amp

 

Length of

 

Rating

Cord in Feet

 

 

 

 

 

 

(120 Volts)

25'

 

50'

100'

150'

 

 

 

 

 

 

10-12

16

 

14

10

8

 

 

 

 

 

 

12-14

16

 

12

10

8

 

 

 

 

 

 

14-16

16

 

12

10

8

 

 

 

 

 

 

16-18

14

 

12

8

8

 

 

 

 

 

 

18-20

14

 

12

8

6

Piping

Plastic or PVC pipe is not designed for use with compressed air. Regardless of its indicated pressure rating, plastic pipe can burst from air pressure. Use only metal pipe for air distribution lines.

If a pipe line is necessary, use pipe that is the same size, or larger than, the air tank outlet. Piping that is too small will restrict the flow of air. If piping is over 100 feet long, use the next larger size. Bury underground lines below the frost line and avoid pockets where condensation can gather and freeze. Apply pressure before underground lines are covered to make sure all pipe joints are free of leaks.

Grounding Instruction WARNING: Risk of electric shock! In the event if a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded. The air compressor is equipped with a cord having a grounding wire with an appropriate

Page 10

Image 10
Contents Scfm @ 40 Psig Scfm @ 90 Psig Minimum Circuit Requirement 15 AmpsTable of Contents Unsafe RiskOperation Tank AccessoriesRisk of Air BurstingExplosion or ElectricShock FireAir Risk fromCompressed Moving PartsGeneral Information GlossaryDuty Cycle ON-RECEIPT InspectionDescription Operation StorageMotor Thermal Overload Installation BREAK-IN Procedures Location of the AIR CompressorAmp Length Rating Cord in Feet Initial Start Up ProcedureExtension Cords 150Daily Start-up Checklist Operating ProceduresWhen you are finished Maintenance Routine Maintenance ScheduleUnits with External Brass Check Valve Replacement Service InstructionsMotor INTO, Weld or Otherwise Modify Troubleshooting GuideNot Over Tighten AIR Tank or IT will WEAKEN.Problem Cause Correction Problem Cause Correction Compressor Maintenance LOG Page Makita Warranty Warranty Policy