Makita owner manual Installation BREAK-IN Procedures, Location of the AIR Compressor

Page 9

reaches “cut-out” pressure. PRESSURE SWITCH: The pressure switch automatically starts the motor when the air tank pressure drops to the factory set “cut-in” pressure. It stops the motor when the air tank pressure reaches the factory set “cut-out” pressure.

SAFETY VALVE: If the pressure switch does not shut off the air compressor at its “cut-out” pressure setting, the safety valve will protect against high pressure by “popping out” at its factory set pressure (slightly higher than the pressure switch “cut-out” setting).

OUTLET PRESSURE GAUGE: The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is controlled by the regulator and is always less or equal to the tank pressure. See “Operating Procedures”.

TANK PRESSURE GAUGE: The tank pressure gauge indicates the air pressure in the tank.

REGULATOR: The air pressure coming from the air tank is controlled by the regulator knob. Turn the knob clockwise to increase pressure and counter- clockwise to decrease pressure. To avoid minor re-adjustment after making a change in pressure setting, always approach the desired pressure from a lower pressure. When reducing from a higher to a lower setting, first reduce to some pressure less than desired pressure. Depending on the air requirements of each particular

accessory, the outlet regulated air pressure may have to be adjusted while you are operating the accessory.

INSTALLATION AND

BREAK-IN

PROCEDURES

LOCATION OF THE AIR COMPRESSOR

Locate the air compressor in a

clean, dry and well-ventilated area. The air intake must be kept

clear of obstructions, which could reduce air delivery of the air compressor. The air compressor should be located at least 12 inches away from the wall or other obstructions that will interfere with the flow of air. The air compressor head and shroud are designed to allow for proper cooling. If humidity is high, an air filter can be installed on the air outlet adapter to remove excessive moisture.

LUBRICATION AND OIL CAUTION: Do not attempt to operate this air compressor without first adding oil to the crankcase. Serious damage will result from even limited operation unless filled with oil and broken in correctly. Make sure to closely follow initial start-up procedures. Compressor oil is provided; on a level surface, please fill the crankcase to proper level indicated on the sight glass.

WARNING: Compressors are shipped without oil. A small

Page 9

Image 9
Contents Minimum Circuit Requirement 15 Amps Scfm @ 40 Psig Scfm @ 90 PsigTable of Contents Risk UnsafeOperation Risk of Air AccessoriesTank BurstingShock ElectricExplosion or FireCompressed Risk fromAir Moving PartsDuty Cycle GlossaryGeneral Information ON-RECEIPT InspectionStorage Description OperationMotor Thermal Overload Location of the AIR Compressor Installation BREAK-IN ProceduresExtension Cords Initial Start Up ProcedureAmp Length Rating Cord in Feet 150Operating Procedures Daily Start-up ChecklistWhen you are finished Routine Maintenance Schedule MaintenanceService Instructions Units with External Brass Check Valve ReplacementMotor Not Over Tighten Troubleshooting GuideINTO, Weld or Otherwise Modify AIR Tank or IT will WEAKEN.Problem Cause Correction Problem Cause Correction Compressor Maintenance LOG Page Warranty Policy Makita Warranty