Disassembly

3. MOTOR

1.

Remove the cabinet.

 

2.

Remove the evaporator.

 

3.

Remove the orifice.

 

4.

Remove the blower.

 

5.

Remove the fan.

 

6.

Remove the control box cover and housing of the

 

 

motor in the control box.

 

7.

Remove the 2 screws which fasten the motor from

 

 

the mount motor. (See Figure 23)

 

8.

Remove the motor.

 

9.

Re-install the components by referring to the

Figure 23

 

removal procedure, above.(See Figure 23)

Electrical Parts

1. OVERLOAD PROTECTOR

1. Remove the cabinet.

2. Remove the nut which fastens the terminal cover.

3. Remove the terminal cover. (See Figure 24)

4. Remove all the leads from the overload protector.

5. Remove the overload protector.

6. Re-install the component by referring to the removal procedure, above.

Figure 24

2.COMPRESSOR

1.Remove the cabinet.

2.Discharge the refrigerant system using a FreonTM

 

Recovery System.

 

 

If there is no valve to attach the recovery system,

 

 

install one (such as a WATCO A-1) before venting

 

 

the FreonTM. Leave the valve in place after

 

 

servicing the system.

 

3.

Remove the overload protector.

 

4.

After purging the unit completely, unbraze the

 

 

suction and discharge tubes at the compressor

 

 

connections.

 

5.

Remove the 3 nuts and the 3 washers which

 

 

fasten the compressor.

 

6.

Remove the compressor. (See Figure 25)

Figure 25

7.Re-install the components by referring to the removal procedure, above.

Service Manual 12

Image 12
Contents Room Air Conditioner Service and Parts Manual Table of Contents Safety Precautions Plug in the power plug properly Do not clean the air conditioner with water Symbols Used in this Manual Outside DimensionsProduct Specifications Operation Location and Function of ControlsAuto Swing Mechanical Parts Front GrilleCabinet Control BOXAir Handling Parts AIR Guide and BlowerFAN and Shroud Electrical Parts MotorOverload Protector Model Touch & Remote Control Type Model Refrigerating CycleEvaporator Pulling Vacuum Schematic Diagram Circuit DiagramElectronic Control Device Components LocationFor Main P.W.B ASM Troubleshooting Guide Piping SystemTroubleshooting Guide Unit runs but poor coolingFails to Start Electric Parts Troubleshooting Guide Possible TroubleCompressor does not operate Romote controller does not operate Room AIR Conditioner Voltage Limits Troubleshooting Guide Troubleshooting Guide Exploded Vie w ReplacementParts list Use Factory Certified Parts