Friedrich CP10E10, CP12E10 manual Electric Parts Troubleshooting Guide, Possible Trouble

Page 22

Troubleshooting Guide

MODEL : BG8000ER, WG8000RY4, WG1000RY4

ELECTRIC PARTS TROUBLESHOOTING GUIDE:

Possible Trouble 1

Is the Trans input power AC 115V?

YES

Is the Trans output power

about AC 14V?

YES

Is output Voltage of IC01D

DC 12V?

YES

Is output Voltage of IC02D

DC 5V?

YES

• The unit does not operate.

NO

 

• Check the Fuse.

 

 

 

 

 

 

• Check the wiring diagram.

 

 

 

 

 

 

 

 

 

 

 

NO

Is shorted the Trans. output?

NO

 

• Check the Main

 

 

 

 

 

 

 

 

P.W.B pattern.

 

 

 

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• Exchange the Trans.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

 

 

 

 

 

 

Exchange D02D~D05D.

 

 

 

 

 

 

 

 

• Exchange IC01D.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NO

• Exchange IC02D.

 

Is the reset circuit all right?

NO

(The No.14 of Micom

 

is 5V.)

 

 

YES

 

 

 

 

 

 

Is the

connection between NO Main and Display

• Exchange IC01A.

• Connect connector

exactly.

all right?

YES

Is the voltage No.18 of Micom

DC 5V?

YES

Exchange Main P.W.B Ass'y.

NO

• Check the P.W.B

pattern.

Service Manual 22

Image 22
Contents Room Air Conditioner Service and Parts Manual Table of Contents Safety Precautions Plug in the power plug properly Do not clean the air conditioner with water Symbols Used in this Manual Outside DimensionsProduct Specifications Operation Location and Function of ControlsAuto Swing Cabinet Mechanical PartsFront Grille Control BOXAIR Guide and Blower Air Handling PartsFAN and Shroud Motor Electrical PartsOverload Protector Model Touch & Remote Control Type Model Refrigerating CycleEvaporator Pulling Vacuum Schematic Diagram Circuit DiagramElectronic Control Device Components LocationFor Main P.W.B ASM Troubleshooting Guide Piping SystemTroubleshooting Guide Unit runs but poor coolingFails to Start Electric Parts Troubleshooting Guide Possible TroubleCompressor does not operate Romote controller does not operate Room AIR Conditioner Voltage Limits Troubleshooting Guide Troubleshooting Guide Exploded Vie w ReplacementParts list Use Factory Certified Parts