Troubleshooting Guide

ROOM AIR CONDITIONER VOLTAGE LIMITS

NAME PLATE RATING

MINIMUM

 

MAXIMUM

 

 

 

 

 

 

 

 

 

 

115V ± 10%

103.5V

 

 

126.5V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

COMPLAINT

 

CAUSE

 

 

REMEDY

 

 

 

 

 

 

Fan motor will not run.

 

No power

 

Check voltage at outlet. Correct if none.

 

 

 

 

 

 

 

 

Power supply cord

 

Check voltage to rotary switch. If none, check

 

 

 

 

 

power supply cord. Replace cord if circuit is

 

 

 

 

 

open.

 

 

 

 

 

 

 

 

Rotary switch

 

Check switch continuity. Refer to wiring diagram

 

 

 

 

 

for terminal identification. Replace switch if

 

 

 

 

 

defective.

 

 

 

 

 

 

 

 

Wire disconnected or

 

Connect wire. Refer to wiring diagram for

 

 

connection loose

 

terminal identification. Repair or replace loose

 

 

 

 

 

terminal.

 

 

 

 

 

 

 

 

Capacitor (Discharge

 

Test capacitor.

 

 

capacitor before testing.)

 

Replace if not within ±10% of manufacturer's

 

 

 

 

 

rating. Replace if shorted, open, or damaged.

 

 

 

 

 

 

 

 

Will not rotate

 

Fan blade hitting shroud or blower wheel hitting

 

 

 

 

 

scroll. Re-align assembly.

 

 

 

 

 

Units using slinger ring condenser fans must

 

 

 

 

 

have 0.22~0.25 inch clearance to the base.

 

 

 

 

 

If necessary, shim up the bottom of the fan motor

 

 

 

 

 

with mounting screw(s).

 

 

 

 

 

Check fan motor bearings; if motor shaft will not

 

 

 

 

 

rotate, replace the motor.

 

 

 

 

 

 

Fan motor runs.

 

Revolves on overload

 

Check voltage. See limits on this page.

 

 

 

 

 

If not within limits, call an electrician.

 

 

 

 

 

Test capacitor.

 

 

 

 

 

Check bearings. Does the fan blade rotate

 

 

 

 

 

freely?

 

 

 

 

 

If not, replace fan motor.

 

 

 

 

 

Pay attention to any change from high speed to

 

 

 

 

 

low speed. If the speed does not change,

 

 

 

 

 

replace the motor.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

25Room Air Conditioner

Image 25
Contents Room Air Conditioner Service and Parts Manual Table of Contents Safety Precautions Plug in the power plug properly Do not clean the air conditioner with water Outside Dimensions Symbols Used in this ManualProduct Specifications Location and Function of Controls OperationAuto Swing Front Grille Mechanical PartsCabinet Control BOXAIR Guide and Blower Air Handling PartsFAN and Shroud Motor Electrical PartsOverload Protector Refrigerating Cycle Model Touch & Remote Control Type ModelEvaporator Pulling Vacuum Circuit Diagram Schematic DiagramElectronic Control Device Components LocationFor Main P.W.B ASM Piping System Troubleshooting GuideUnit runs but poor cooling Troubleshooting GuideFails to Start Possible Trouble Electric Parts Troubleshooting GuideCompressor does not operate Romote controller does not operate Room AIR Conditioner Voltage Limits Troubleshooting Guide Troubleshooting Guide Exploded Vie w ReplacementParts list Use Factory Certified Parts