Friedrich CP10E10, CP12E10 manual Romote controller does not operate

Page 24

Troubleshooting Guide

Possible Trouble 5

• Romote controller does not operate.

Is the voltage of Battery

NO

 

 

 

• Exchange the battery.

about over 2.3V?

 

 

 

 

 

 

 

 

YES

 

 

 

 

 

 

 

 

 

Is the voltage No.16

of CN-DISP1 on Main P.W.B

Ass'y DC 5V?

YES

Is the connection of

CN-DISP1 all right?

YES

• Exchange Receiver Ass'y.

Possible Trouble 6

NO

• Check the P.W.B pattern.

 

NO

 

• Connect connector to

 

 

 

 

 

 

CN-DISP1 exactly.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

• It displays abnormally on Display P.W.B Ass'y.

Is the IC01G all right?

YES

NO

Is the connection of

CN-DISP1 all right?

YES

Does the Q01G,

Q02G, Q03G Q04G operate normally

on main P.W.B Ass'y?

YES

Exchange the display P.W.B Ass'y.

NO

NO

NO

• Exchange IC01G.

• Connect connector to CN-DISP1 exactly.

• Exchange Q01G, Q02G, Q03G, Q04G

Service Manual 24

Image 24
Contents Room Air Conditioner Service and Parts Manual Table of Contents Safety Precautions Plug in the power plug properly Do not clean the air conditioner with water Symbols Used in this Manual Outside DimensionsProduct Specifications Operation Location and Function of ControlsAuto Swing Mechanical Parts Front GrilleCabinet Control BOXAir Handling Parts AIR Guide and BlowerFAN and Shroud Electrical Parts MotorOverload Protector Model Touch & Remote Control Type Model Refrigerating CycleEvaporator Pulling Vacuum Schematic Diagram Circuit DiagramElectronic Control Device Components LocationFor Main P.W.B ASM Troubleshooting Guide Piping SystemTroubleshooting Guide Unit runs but poor coolingFails to Start Electric Parts Troubleshooting Guide Possible TroubleCompressor does not operate Romote controller does not operate Room AIR Conditioner Voltage Limits Troubleshooting Guide Troubleshooting Guide Exploded Vie w ReplacementParts list Use Factory Certified Parts