3.3 TROUBLESHOOTING GUIDE

In general, possible trouble is classified in two kinds.

The one is called Starting Failure which is caused by an electrical defect. The other is Ineffective Air Con- ditioning caused by a defect in the refrigeration circuit and improper application.

Unit is running but cooling is ineffective.

Ineffective Cooling

Check cold air circulation for smooth flow.

Dirty indoor coil (heat exchanger)

Malfunction of fan.

Clogging air filter.

Obstruction at air outlet.

Remove obstruction.

Check for restriction in refri - geration circuit.

Remove restriction in refrigeration circuit.

Check outdoor coil (heat exchanger) and fan operation.

Check for gas leakage.

Repair gas leak.

Replacement of unit if the unit is beyond repair.

Satisfactory operation with temperature difference of inlet & outlet air; 18~26°F.

Check heat load increase.

Clean condenser.

Not on dedicated circuit.

Check inside gas pressure.

Adjust refrigerant charge.

Malfunction of compressor.

Replacement of compressor.

—13—

Image 14
Contents Room Air Conditioner Service and Parts Manual Contents Preface Locations of Controls Disassembly Instructions ORIFICE, Turbo FAN and FAN AIR Handling PartsAIR Guide Upper Overload Protector Electrical PartsAIR Guide Thermistor CompressorCapacitor Control BoardCondenser Power CordRefrigerant Cycle Evaporator Capillary Tube0A-Pulling Vacuum Electrical Data USE of Extension CordsPiping System Condenser CoilsTroubleshooting Guide Unit is running but cooling is ineffectiveFails to Start Room AIR Conditioner Voltage Limits 203/$,17 $86 50 Complaint Cause Remedy Circuit Diagram 3/29 W0CZZ Use Factory Certified Parts