Friedrich CP05N10A manual Refrigerant Cycle, Power Cord, Condenser

Page 9

2.3.6 POWER CORD

1.Disconnect the unit from source of power.

2.Remove the front grille. (Refer to Section 2.1.1)

3.Remove the cabinet. (Refer to Section 2.1.2)

4.Remove a screw that secures control panel to base pan. (Refer to Section 2.1.3)

5.Pulls the control board toward you.

6.Disconnect the 2 receptacles and remove the grounding screw.

7.Remove a screw securing the clip with cord to the control panel.

8.Pull the power cord.

9.Re-install by referring to procedures above.

2.4 REFRIGERANT CYCLE

2.4.1 CONDENSER

1.Remove the cabinet. (Refer to Section 2.1.2)

2.Discharge the refrigerant by using a refrigerant recovery system.

3.Remove the air guide. (Refer to Section 2.2.1)

4.Remove 2 screws which fasten the condenser.

5.After discharging the refrigerant completely, unbraze the interconnecting tube at the condenser connections.

6.Remove the condenser.

7.Re-install by referring to the procedures above.

Figure 18

Figure19

—8—

Image 9
Contents Room Air Conditioner Service and Parts Manual Contents Preface Locations of Controls Disassembly Instructions AIR Handling Parts AIR Guide UpperORIFICE, Turbo FAN and FAN Electrical Parts AIR GuideOverload Protector Capacitor CompressorThermistor Control BoardPower Cord Refrigerant CycleCondenser Capillary Tube Evaporator0A-Pulling Vacuum USE of Extension Cords Electrical DataCondenser Coils Piping SystemUnit is running but cooling is ineffective Troubleshooting GuideFails to Start Room AIR Conditioner Voltage Limits 203/$,17 $86 50 Complaint Cause Remedy Circuit Diagram 3/29 W0CZZ Use Factory Certified Parts