Friedrich 36, 24, 60, 18, 49 Section I General Specifications, VERT-I-PAKMODEL Identification Guide

Page 4

Section I – General Specifications

VERT-I-PAK®MODEL IDENTIFICATION GUIDE

 

MODEL NUMBER

V

H

B

36

K

10

RT

A

 

SERIES

 

 

 

 

 

 

 

 

ENGINEERING CODE

 

V=Vertical Series

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPTIONS

 

E=Cooling with or without electric heat

 

 

 

 

 

 

 

 

H=Heat Pump

 

 

 

 

 

 

 

RT = Standard Remote Operation

 

DESIGN SERIES

 

 

 

 

 

 

 

 

 

A = 32" Cabinet

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ELECTRIC HEATER SIZE

 

B = 68" Cabinet

 

 

 

 

 

 

 

NOMINAL CAPACITY

 

 

 

 

 

 

B-Series

 

B-Series (Btu/h)

 

 

 

 

 

 

 

 

 

18 = 18,000

36 = 36,000 60 = 60,000

 

 

 

 

 

05

= 5.0 KW

 

24 = 24,000

42 = 42,000

 

 

 

 

 

 

10= 10.0 KW

 

30 = 30,000

49 = 49,000

 

 

 

 

 

15

= 15.0 KW

 

VOLTAGE

 

 

 

 

 

 

20

= 20.0 KW

 

K = 208/230V-1Ph-60Hz

 

 

 

 

 

25

= 25.0 KW

B-SERIES CHASSIS SPECIFICATIONS

 

M O D E

L S :

 

V(E,H)B18K05

 

V(E,H)B18K10

V(E,H)B24K05

V(E,H)B24K10

V(E,H)B30K10

V(E,H)B30K15

V(E,H)B36K10

V(E,H)B36K15

 

C O O L I N G

D A T A :

 

 

 

 

 

 

 

 

Cooling Cap.

 

17000

 

17000

22000

22000

30000

30000

35000

35000

 

Cooling Power (W)

 

1700

 

1700

2200

2200

2900

2900

3500

3500

 

 

SEER

 

10.0

 

10.0

10.0

10.0

10.0

10.0

10.0

10.0

 

Cooling SHR

 

0.78

 

0.78

0.75

0.75

0.70

0.70

0.70

0.70

 

E L E C T R I C A L

H E A T

D A T A :

 

 

 

 

 

 

 

Heater Size (KW)

 

5.0

 

10.0

5.0

10.0

10.0

15.0

10.0

15.0

 

Heating Cap. (Btu/h)

 

17050

 

34100

17050

34100

34100

51150

34100

51150

 

Heating Power (W)

 

5000

 

10000

5000

10000

10000

15000

10000

15000

 

Heating Current (A)

 

20.8

 

41.6

20.8

41.6

41.6

62.4

41.6

62.4

 

H E A T

P U M P

D A T A :

 

 

 

 

 

 

 

 

Heating Cap. (Btu/h)

 

17000

 

17000

22000

22000

30000

30000

34000

34000

 

Heating Power (W)

 

1650

 

1650

2000

2000

2600

2600

3300

3300

 

Heating Current (A)

 

7.3

 

7.3

9.3

9.3

12.0

12.0

15.0

15.0

 

 

COP

 

3.0

 

3.0

3.2

3.2

3.2

3.2

3.0

3.0

 

E L E C T R I C A L

D A T A :

 

 

 

 

 

 

 

 

 

Voltage (V)

 

230/208

 

230/208

230/208

230/208

230/208

230/208

230/208

230/208

 

LRA - Comp. (A)

 

42.5

 

42.5

56.0

56.0

72.5

72.5

88.0

88.0

 

Min. Ckt. Amps (A)+

 

(14) 26

 

(14) 52

(16.7) 26

(16.7) 52

(22.8)52

(22.8)26,52

(27.9)52

(27.9) 26,52

 

Power Connection

 

Hard Wire

 

Hard Wire

Hard Wire

Hard Wire

Hard Wire

Hard Wire

Hard Wire

Hard Wire

 

P H Y S I C A L

D A T A :

 

 

 

 

 

 

 

 

Unit Width (in.)

 

30.00

 

30.00

30.00

30.00

30.00

30.00

30.00

30.00

 

Unit Depth (in.)

 

21.00

 

21.00

21.00

21.00

21.00

21.00

21.00

21.00

 

Unit Height (in.)

 

68.00

 

68.00

68.00

68.00

68.00

68.00

68.00

68.00

 

Shipping Weight (lbs.)

 

320

 

320

320

320

330

330

340

340

 

A I R F L O W

D A T A :

 

 

 

 

 

 

 

 

Indoor CFM

 

640

 

640

800

800

1000

1000

1050

1050

 

Fresh Air CFM

 

65

 

65

65

65

65

65

65

65

 

Indoor Motor

 

1/3

 

1/3

1/3

1/3

1/3

1/3

1/3

1/3

 

Indoor Motor Amps

 

1.0

 

1.0

1.0

1.0

1.8

1.8

2.5

2.5

 

Outdoor Motor

 

1/3

 

1/3

1/3

1/3

1/3

1/3

1/2

1/2

 

Outdoor Motor Amps

 

1.4

 

1.4

1.4

1.4

2.2

2.2

3.0

3.0

 

 

 

 

 

 

 

 

 

 

 

 

 

4

Image 4
Contents Installation Table of Contents Safety Considerations Supplies Needed for InstallationGeneral Recommendations DOS and Donts Unpack and Inspect UnitSection I General Specifications VERT-I-PAKMODEL Identification GuideCondensate Drain Exit Above Floor Section III Installation Indoor and Outdoor AIR Requirements Unit ConfigurationOutdoor Air System VPBWP3 8/14 Wall Plenum VPBWP4 8/14 Wall PlenumVPBWP5 8/14 Wall Plenum VPBWP6 8/14 Wall PlenumDucted Condenser Air Typical Ducted Outside Air ConfigurationOutdoor Fan Performance Indoor Fan Performance Indoor-Air Conditioned Supply Air SystemReturn Air Options Electrical Grounding Power Supply Cooling and FanThermostat Mounting and Wiring A. Thermostat Location Thermostat Mounting and WiringWire Thermostat Cable to Unit Terminal Strip Thermostat WiringInstallation Final Checklist Test RunIdentifying Your System Important FactsHeat Mode Operation Operating the VERT-I-PAK Thermostat OperationHeating Cycle Cooling CycleDefrost Cycle Performing Routine Maintenance Replace AIR FilterInspect and Clean Condensate Drain Inspect and Clean INDOOR-AIR CoilInspect OUTDOOR-AIR Intake and Exhaust Use Factory-Certified Parts