Craftsman 921.1664 operating instructions Operating Procedures

Page 7

Operating Procedures

Dally Start-Up Procedures

1, Set the Auto-On/Off lever to the Off position, 2, inspect the air compressor, air hose, and any

accessories/tools being used for damage or obstruction, if any of these mentioned items are in need of repair/ replacement, contact your local authorized service dealer before use,

3, Close the drain valve,

4, Check the o11[eve[ of the pump,

5, Connect the air hose to the quick connect socket on the regulator assembly by inserting the quick connect plug on the air hose into the quick connect socket, The quick connect socket collar wii[ snap forward and lock the plug into place providing an air tight sea[ between the socket and plug, To release the air hose push the collar back on the quick connect socket,

Daily Shut-Down Procedures

1, Set the Auto-On/Off [ever to the Off position, 2, Unplug the power cord from the receptacle,

3, Set the outlet pressure to zero on the regulator,

4, Remove any air tools or accessories, When draining the tank, always use ear and eye protection, Drain the tank in a suitable location; condensation wii[ be present in most cases of draining,

5, Open the drain valve allowing air to bleed from the tank, After ai[ of the air has bled from the tank, dose the drain valve to prevent debris buildup in the valve,

6, Plug the power cord into the proper receptacle,

7, Turn the Auto-On/Off [ever to the On-Auto position and the compressor wii[ start and build air pressure in the tank to cut-out pressure and then shut off automatically,

8, Adjust the regulator to a PSi setting that is needed for your application and be sure it is within the safety standards required to perform the task, if using a pneumatic too[, the manufacturer should have recommendations in the manual for that particular too[ on operating PSi settings,

9, The air compressor is now ready for use, The following inflation and cleaning accessories packaged with this unit should only be operated at maximum pressure

of 90PSi: blow gun, rubber-tapered nozzle, inflation needles, adapter, and Mow gun adapter,

When draining the tank, always use ear and eye protection, Drain the tank in a suitable Iocationl condensation wiii be present in most cases of draining,

Water that remains in the tank during storage will corrode and weaken the air tank which could cause the tank to rupture, To avoid serious injury, be sure to drain the tank after each use or daily,

Image 7
Contents AiR Compressor GaHton OiJ Lubricated Table of Contents Risk of Burns Risk of Falling Risk from Flying Objects Safety SymbolsMmpottant Safety mnstructions and Guidelines Save aH instructionsRisk Eectrica Shock ×posion or Fire Risk of Bursting SpecificationsOssary Duty CycleParts & Features Installation & Assembly Operating Procedures Storage MaintenanceTroubleshootingGuide Air Compressor Model Exploded View Part # Air Compressor Mode Parts ListGARANTiA DE UN ANO Para EL Compresor DE Aire Craftsman ContenidoRiesgo de quemaduras Riesgo de cada Smbolos comunes de seguridadLnstrucciones y pautas de seguridad importantes Guarde todas las instruccionesRiesgo para la respiraci6n EspecificacionesGlosario Cicio de trabaoPartes y caracteristicas Ensamblaje Procedimientos de operaci6n Nota MantenimientoPosible CORRECCI6N Oiagn6stico y correcci6n de fallasCall anytime, day or night U.S.A. and Canada Your Home