Craftsman 919.724271 How to Stop, Before Starting, Check Valve, Pressure Release Valve

Page 14

Check Valve: When the air compressor is operating, the check valve is “open”, allowing compressed air to enter the air tank. When the air compressor reaches “cut-out” pressure, the check valve “closes”, allowing air pressure to remain inside the air tank.

Check Valve

Pressure Release Valve: The pressure release valve, located on the side of the pressure switch, is designed to automatically release compressed air from the compressor head and the outlet tube when the air compressor reaches “cut-out” pressure or is shut off. The pressure release valve allows the motor to restart freely. When the motor stops running, air will be heard escaping from this valve for a few seconds. No air should be heard leaking when the motor is running, or continuous leaking after unit reaches “cut-out” pressure.

Pressure

Release

Valve

Air Intake Filter (not shown) This filter is designed to clean air coming into the pump. This filter must always be clean and ventilation openings free from obstructions. See "Maintenance".

How to Use Your Unit

How to Stop:

1.Set the On/Auto/Off lever to “OFF”.

Before Starting

Break-in Procedure

Serious damage may result if the

following break-in instructions are not closely followed.

This procedure is required before the air compressor is put into service and when the check valve or a complete compressor pump has been replaced.

1.Make sure the On/Auto/Off lever is in the "OFF" position.

2.Recheck all wiring. Make sure wires are secure at all terminals connections. Make sure all contacts move freely and are not obstructed.

3.Open the globe valve fully to permit air to escape and prevent air pressure build up in the air tank during the break-in period.

4.Move the On/Auto/Off lever to "ON/AUTO" position. The compressor will start.

5.Run the compressor for 15 minutes. Make sure the globe valve is open and there is minimal air pressure build-up in tank.

6.Check all air line fittings and connections/piping for air leaks by applying a soap solution. Correct if necessary. NOTE: Minor leaks can cause the air compressor to overwork, resulting in premature breakdown or inadequate performance.

D25050

14- ENG

Image 14
Contents AIR Compressor Sold by Sears Canada, Inc. Toronto, Ont. M5B 2B8Table of Contents Important Safety Instructions Specification ChartSafety Guidelines Definitions Model No 919-724270Hazard Risk of Explosion or FireRisk of Bursting Risk from Flying ObjectsRisk of Electrical Shock Risk to BreathingRisk of Falling Risk of BurnsRisk from Moving Parts Risk of Unsafe Operation Glossary AccessoriesAccessories Duty CycleAssembly Installation Air Distribution System Wiring Instructions Voltage and Circuit Protection Risk of ElectricalTypical Compressed AIR Distribution System Description of Operation OperationKnow Your Air Compressor Drain ValveCheck Valve How to StopBefore Starting Pressure Release ValveHow to Start Before Each Start-UpCustomer Responsibilities MaintenanceTo Check Safety Valve To Drain TankInspect Air Lines and Fittings for Leaks Air Filter Inspection and ReplacementAir Compressor Pump Intake and Exhaust Valves MotorNut Outlet Tube Pressure Relief Check Valve Service and AdjustmentsTo Replace or Clean Check Valve Screwdriver Open position nothing is visibleStorage Troubleshooting Problem Cause CorrectionProblem Cause Correction Check wiring connection Table DES Matières Sears Canada, Inc., Toronto, Ont. M5B 2B8Consignes DE Sécurité Importantes Tableau DES SpécificationsMesures DE Sécurité Définitions Risque D’EXPLOSION OU D’INCENDIE RisqueRisque D’ÉCLATEMENT Risque DE Projection D’OBJETSRisque DE Choc Électrique Risque PAR InhalationRisque DE Chute Risque DE BrûluresRisque Relié AUX Pièces Mobiles Risque Dune Utilisation Dangereuse Accessoires AccessoiresCycle DE Service LexiqueAssemblage Tension et protection des circuits Directives de câblageDirectives DE Mise À LA Terre Système de distribution dairSystème DE Distribution Dair Typique Description du fonctionnement UtilisationFamiliarisez-vous avec votre compresseur dair Arrêt de lappareil Utilisation de lappareilAvant le démarrage Procédures de rodageAvant chaque mise en marche Mise en marcheVérification de la soupape de sûreté EntretienResponsabilités du client Vidange du réservoirFiltre à air Filtre à air Inspection et remplacementMoteur Remplacement ou nettoyage de la soupape de retenue Entretien ET RéglagesRangement Serrer DépannageProblème Cause Correction Peut éclater ou exploserCognements Pas Surcharges déclenché D25050 ENG ENG D25050 Get it fixed, at your home or ours