Craftsman 919.15216 owner manual Installation, Location of the Air Compressor, Unpacking

Page 10

assembly

Unpacking

1.Remove unit from carton and discard all packaging.

INSTALLATION

HOW TO SET UP YOUR UNIT

Location of the Air Compressor

Locate the air compressor in a clean, dry and well ventilated area.

The air compressor should be located at least 12" (30.5 cm) away from the wall or other obstructions that will interfere with the flow of air.

The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings.

Grounding Instructions

Risk of Electrical Shock. In the event

of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded.

The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see following illustrations).

1.The cord set and plug with this unit contains a grounding pin. This plug MUST be used with a grounded outlet.

IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances.

2.Make sure the outlet being used has the same configuration as the grounded plug. DO NOT USE AN ADAPTER. See illustration.

Plug

Grounded

Outlets

Grounding Pin

3.Inspect the plug and cord before each use. Do not use if there are signs of damage.

4.If these grounding instructions are not completely understood, or if in doubt as to whether the compres- sor is properly grounded, have the installation checked by a qualified electrician.

Risk of Electrical

Shock. IMPROPER

GROUNDING CAN RESULT IN ELECTRICAL SHOCK.

Do not modify the plug provided. If it does not fit the available outlet, a correct outlet should be installed by a qualified electrician.

Repairs to the cord set or plug MUST be made by a qualified elec- trician.

N014212

10 - ENG

Image 10
Contents Air Compressor Table of Contents WarrantyImportant Safety Instructions Specification ChartSafety Guidelines Definitions Model No 919.152160Hazard Risk of explosion or fire What can happen How to prevent itWhat can happen How to prevent it Risk to Breathing AsphyxiationAttachments & accessories Risk of BurstingElectrical Grounding Failure to Risk of Electrical Shock What can happen How to prevent itTires Refer to Grounding InstructionsRisk of Hot surfaces Risk from Flying Objects What can happen How to prevent itRisk from Moving Parts Risk of Falling Risk of Unsafe Operation What can happen How to prevent itRisk from noise Accessories AccessoriesGlossary Unpacking InstallationLocation of the Air Compressor Risk of Electrical Shock. ImproperExtension Cords Voltage and Circuit ProtectionKnow Your Air Compressor OperationDescription of Operation Before Starting How to StopBefore Each Start-Up To Check Safety Valve MaintenanceHow to Start Customer ResponsibilitiesTo Replace or Clean Check Valve Service and AdjustmentsTo Replace Regulator Manifold Storage Carefully slide pump from brackets and out of the wayTroubleshooting Description Overload Protection AIR Compressor Diagram Air Compressor Model NumberParts List Pump Diagram Parts List N0142128 Master Protection Agreements Contratos de Protección MaestraSears Parts and Repair Center MY-HOMECanada
Related manuals