4.Remove the hose by removing the hose clamp. NOTE: The hose clamp is not reusable. You must purchase a new hose clamp, see the Parts List or purchase a standard hose clamp at a local hardware store.
Regulator
Manifold
Hose Clamp
5.Remove pump mounting screws securing pump (one on each side).
Pump Mounting Screw
6.Carefully slide pump from brackets and out of the way.
Pump shown moved out of the way
Regulator
Manifold
7.Using an adjustable wrench remove the regulator manifold.
8.Apply pipe sealant to new regulator manifold and assemble, tighten with wrench.
9.Reapply pipe sealant to safety valve.
10.Reassemble all components in reverse order of removal. Make sure to orient gauges to read correctly and use wrenches to tighten all components.
STORAGE
Before you store the air compressor, make sure you do the following:
1.Review the Maintenance section on the preceding pages and perform scheduled maintenance as necessary.
2.Set the On/Off switch to "Off" and unplug unit.
3.Turn the regulator counterclock- wise and set the outlet pressure to zero.
4.Remove the air tool or accessory.
5.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.
6.Drain water from air tank by opening drain valve on bottom of tank.
Risk of Bursting.
Water will condense
in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.
7.After the water has been drained, close drain valve by turning clockwise.
NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.
8.Protect the electrical cord and air hose from damage (such as being stepped on or run over).
Wind them loosely around the compressor handle.
9.Store the air compressor in a clean and dry location.
N014212 | 16 - ENG |