Craftsman 919.15216 owner manual Storage, Carefully slide pump from brackets and out of the way

Page 16

4.Remove the hose by removing the hose clamp. NOTE: The hose clamp is not reusable. You must purchase a new hose clamp, see the Parts List or purchase a standard hose clamp at a local hardware store.

Regulator

Manifold

Hose Clamp

5.Remove pump mounting screws securing pump (one on each side).

Pump Mounting Screw

6.Carefully slide pump from brackets and out of the way.

Pump shown moved out of the way

Regulator

Manifold

7.Using an adjustable wrench remove the regulator manifold.

8.Apply pipe sealant to new regulator manifold and assemble, tighten with wrench.

9.Reapply pipe sealant to safety valve.

10.Reassemble all components in reverse order of removal. Make sure to orient gauges to read correctly and use wrenches to tighten all components.

STORAGE

Before you store the air compressor, make sure you do the following:

1.Review the Maintenance section on the preceding pages and perform scheduled maintenance as necessary.

2.Set the On/Off switch to "Off" and unplug unit.

3.Turn the regulator counterclock- wise and set the outlet pressure to zero.

4.Remove the air tool or accessory.

5.Pull ring on safety valve allowing air to bleed from the tank until tank pressure is approximately 20 psi. Release safety valve ring.

6.Drain water from air tank by opening drain valve on bottom of tank.

Risk of Bursting.

Water will condense

in the air tank. If not drained, water will corrode and weaken the air tank causing a risk of air tank rupture.

7.After the water has been drained, close drain valve by turning clockwise.

NOTE: If drain valve is plugged, release all air pressure. The valve can then be removed, cleaned, then reinstalled.

8.Protect the electrical cord and air hose from damage (such as being stepped on or run over).

Wind them loosely around the compressor handle.

9.Store the air compressor in a clean and dry location.

N014212

16 - ENG

Image 16
Contents Air Compressor Table of Contents WarrantySpecification Chart Safety Guidelines DefinitionsImportant Safety Instructions Model No 919.152160Risk of explosion or fire What can happen How to prevent it What can happen How to prevent itHazard Risk to Breathing AsphyxiationAttachments & accessories Risk of BurstingRisk of Electrical Shock What can happen How to prevent it TiresElectrical Grounding Failure to Refer to Grounding InstructionsRisk of Hot surfaces Risk from Flying Objects What can happen How to prevent itRisk from Moving Parts Risk of Falling Risk of Unsafe Operation What can happen How to prevent itRisk from noise Accessories AccessoriesGlossary Installation Location of the Air CompressorUnpacking Risk of Electrical Shock. ImproperExtension Cords Voltage and Circuit ProtectionKnow Your Air Compressor OperationDescription of Operation Before Starting How to StopBefore Each Start-Up Maintenance How to StartTo Check Safety Valve Customer ResponsibilitiesTo Replace or Clean Check Valve Service and AdjustmentsTo Replace Regulator Manifold Storage Carefully slide pump from brackets and out of the wayTroubleshooting Description Overload Protection AIR Compressor Diagram Air Compressor Model NumberParts List Pump Diagram Parts List N0142128 Master Protection Agreements Contratos de Protección MaestraSears Parts and Repair Center MY-HOMECanada