Craftsman 919.15216 owner manual Know Your Air Compressor, Description of Operation

Page 12
Drain Valve

OPERATION

Know Your Air Compressor

READ THIS OWNER’S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR UNIT. Compare the illustrations with your unit to familiarize yourself with the location of various controls and adjustments. Save this manual for future reference.

Tank Outlet

Pressure Pressure

Gauge Gauge

On(I)/Off(O) Switch

Safety Valve

Regulator

Quick

Connect

 

Description of Operation

Become familiar with these controls before operating the unit.

On(I)/Off(O) Switch: Place this switch in the On (I) position to provide automatic power to the pressure switch and Off (O) to remove power at the end of each use.

Pressure Switch (not shown): The pressure switch automatically starts the motor when the air tank pressure drops below the factory set "cut-in" pressure. It stops the motor when the air tank pressure reaches the factory set "cut-out" pressure.

Safety Valve: If the pressure switch does not shut off the air compressor at its "cut-out" pressure setting, the safety valve will protect against high pressure by "popping out" at its factory set pressure (slightly higher than the pressure switch "cut-out" setting).

Tank Pressure Gauge: The tank pressure gauge indicates the reserve air pressure in the tank.

Outlet Pressure Gauge: The outlet pressure gauge indicates the air pressure available at the outlet side of the regulator. This pressure is

controlled by the regulator and is always less than or equal to the tank pressure.

Regulator: Controls the air pressure shown on the outlet pressure gauge. Turn regulator knob clockwise to increase pressure and counterclockwise to decrease pressure.

Cooling System (not shown): This compressor contains an advanced design cooling system. At the heart of this cooling system is an engineered fan. It is perfectly normal for this fan to blow air through the vent holes

in large amounts. You know that the cooling system is working when air is being expelled.

Air Compressor Pump (not shown): Compresses air into the air tank. Working air is not available until the compressor has raised the air tank pressure above that required at the air outlet.

Drain Valve: The drain valve is located at the base of the air tank and is used to drain

condensation at the end of each use.

N014212

12 - ENG

Image 12
Contents Air Compressor Table of Contents WarrantySpecification Chart Safety Guidelines DefinitionsImportant Safety Instructions Model No 919.152160Risk of explosion or fire What can happen How to prevent it What can happen How to prevent itHazard Risk to Breathing AsphyxiationAttachments & accessories Risk of BurstingRisk of Electrical Shock What can happen How to prevent it TiresElectrical Grounding Failure to Refer to Grounding InstructionsRisk from Flying Objects What can happen How to prevent it Risk of Hot surfacesRisk from Moving Parts Risk of Unsafe Operation What can happen How to prevent it Risk of FallingRisk from noise Accessories AccessoriesGlossary Installation Location of the Air CompressorUnpacking Risk of Electrical Shock. ImproperExtension Cords Voltage and Circuit ProtectionOperation Know Your Air CompressorDescription of Operation How to Stop Before StartingBefore Each Start-Up Maintenance How to StartTo Check Safety Valve Customer ResponsibilitiesService and Adjustments To Replace or Clean Check ValveTo Replace Regulator Manifold Storage Carefully slide pump from brackets and out of the wayTroubleshooting Description Overload Protection AIR Compressor Diagram Air Compressor Model NumberParts List Pump Diagram Parts List N0142128 Master Protection Agreements Contratos de Protección MaestraMY-HOME Sears Parts and Repair CenterCanada