PROBLEM | CAUSE  | CORRECTION  | 
  | 
  | 
  | 
Regulator will not shut  | Damaged regulator.  | Replace.  | 
off air outlet.  | 
  | 
  | 
  | 
  | 
  | 
Motor will not run.  | Fuse blown, circuit  | Check fuse box  | 
  | breaker tripped.  | for blown fuse and  | 
  | 
  | replace as necessary.  | 
  | 
  | Reset circuit breaker.  | 
  | 
  | Do not use a fuse or  | 
  | 
  | circuit breaker with  | 
  | 
  | higher rating than  | 
  | 
  | that specified for your  | 
  | 
  | particular branch circuit.  | 
  | 
  | Check for proper fuse.  | 
  | 
  | You should use a time  | 
  | 
  | delay fuse.  | 
  | 
  | Check for low voltage  | 
  | 
  | problem.  | 
  | 
  | Check the extension  | 
  | 
  | cord.  | 
  | 
  | Disconnect the other  | 
  | 
  | electrical appliances  | 
  | 
  | from circuit or operate  | 
  | 
  | the compressor on its  | 
  | 
  | own branch circuit.  | 
  | Extension cord is wrong  | Check the extension  | 
  | length or gauge.  | cord.  | 
  | Loose electrical  | Check wiring  | 
  | connections.  | connection inside  | 
  | 
  | terminal box.  | 
  | Faulty motor.  | Have checked by  | 
  | 
  | a Trained Service  | 
  | 
  | Technician.  | 
  | Motor overload protec-  | Refer to Motor  | 
  | tion switch has tripped  | Overload Protection | 
  | 
  | under Operation.  | 
  | 
  | If motor overload  | 
  | 
  | protection trips  | 
  | 
  | frequently, contact  | 
  | 
  | a Trained Service  | 
  | 
  | Technician.  | 
19 - ENG  | N014212  |