Craftsman 919.167362 Installation, Location of the Air Compressor, Grounding Instructions

Page 10

INSTALLATION

HOW TO SET UP YOUR UNIT

Location of the Air Compressor

Locate the air compressor in a clean, dry and well ventilated area. The air compressor should be located at least 12" away from the wall or other obstructions that will interfere with the flow of air. The air compressor pump and shroud are designed to allow for proper cooling. The ventilation openings on the compressor are necessary to maintain proper operating temperature. Do not place rags or other containers on or near these openings. The air filter must be kept clear of obstructions which could reduce air flow to the air compressor.

GROUNDING INSTRUCTIONS

RISK OF ELECTRICAL

SHOCK. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current. This air compressor must be properly grounded.

The portable air compressor is equipped with a cord having a grounding wire with an appropriate grounding plug (see following illustrations). The plug must be used with an outlet that has been installed and grounded in accordance with all local codes and ordinances.

1.The cord set and plug with this unit contains a grounding pin. This plug MUST be used with a grounded outlet.

IMPORTANT: The outlet being used must be installed and grounded in accordance with all local codes and ordinances.

2.Make sure the outlet being used has the same configuration as the grounded plug. DO NOT USE AN ADAPTER. See illustration.

3.Inspect the plug and cord before each use. Do not use if there are signs of damage.

Plug

Grounded

Outlets

Grounding Pin

4.If these grounding instructions are not completely understood, or if in doubt as to whether the compressor is properly grounded, have the installation checked by a qualified electrician.

IMPROPER GROUNDING CAN

RESULT IN ELECTRICAL SHOCK.

Do not modify the plug provided. If it does not fit the available outlet, a correct outlet should be installed by a qualified electrician. Repairs to the cord set or plug MUST be made by a qualified electrician.

D28409

10- ENG

Image 10
Contents AIR Compressor Table of Contents Safety Guidelines Definitions Specification ChartImportant Safety Instructions Hazard What Could HappenWhat can Happen Hazard Never operate the compressor with Belt can cause serious injury if theyHazard Glossary AccessoriesAccessories Duty CycleGrounding Instructions InstallationLocation of the Air Compressor Risk of ElectricalExtension Cords Voltage and Circuit ProtectionKnow Your Air Compressor OperationDescription of Operation Before First Start-up How to StopAir Compressor Pump not shown How to Start Before Each Start-UpCustomer Responsibilities MaintenanceTo Check Safety Valve To Drain TankOutlet Tube Nut Pressure Relief Tube Check Valve Service and AdjustmentsTo Replace or Clean Check Valve Screwdriver Open position nothing is visibleNipple To Replace RegulatorOutlet Pressure Gauge Regulator Quick Connect Regulator ArrowStorage Troubleshooting Problem Cause CorrectionPressure reading Problem Cause Correction AIR Compressor Diagram Air Compressor Model NumberParts List KEY Part Number DescriptionPump Diagram Not Illustrated Garantía Completa POR UN AÑO Compresor DE Aire ContenidoGarantía Sears, Roebuck and Co., Dept WA, Hoffman Estates, ILResultar en lesiones menores o Definiciones DE Normas DE SeguridadModelo Nº 919-167362 ModeradasInstrucciones Importantes DE Seguridad Guarde Estas InstruccionesAgregados Y Accesorios D28409 30- SP Riesgo DE Caida Advertencia Riesgo DE Quemaduras ¿QUÉ Puede OCURRIR?Advertencia Riesgo DE Operación Insegura ¿QUÉ Puede OCURRIR? Ciclo DE Servicio GlosarioAccesorios AccesoriosUbicación del compresor de aire InstalaciónCómo Preparar LA Unidad Instrucciones Para Conectar a TierraCables de extensión eléctrica Protección del voltaje y del circuitoConozca su compresor de aire OperaciónDescripción de operaciones Cómo detenerla Cómo utilizar su unidadAntes de poner en marcha Antes de cada puesta en marcha Cómo poner en marchaCómo verificar la válvula de seguridad MantenimientoResponsabilidades del cliente Cómo drenar el tanqueTubo de salida Tuerca Servicio Y AjustesPara reemplazar o limpiar la válvula Reguladora Tubo aliviador de presiónNiple Para reemplazar el reguladorRegulador Conector rápido Regulador FlechaAlmacenaje Guía DE Diagnóstico DE Problemas Problema Causa CorrecciónDesciende cuando El motor no funciona D28409 46- SP 47- SP D28409 Canada MY-HOMESears Parts and Repair Center SU-HOGARSM