5.Run the compressor for 15 minutes. Make sure the drain valve is open and there is minimal air pressure build-up in tank.

6.After 15 minutes, close the drain valve (clockwise). The air receiver will fill to "cut-out" pressure and the motor will stop.

The compressor is now ready for use.

Before Each Start-Up:

1.Place On/Auto/Off lever to "OFF" and close air regulator.

2.Pull regulator knob out, turn counterclockwise until it stops. Push knob in to lock in place.

3.Attach hose and accessories. NOTE: The hose or accessory will require a quick connect plug if the air outlet is equipped with a quick connect socket.

Too much air pressure causes a

hazardous risk of bursting. Check the manufacturer’s maximum pressure rating for air tools and accessories. The regulator outlet pressure must never exceed the maximum pressure rating.

How to Start:

1.Turn the On/Auto/Off lever to "AUTO" and allow tank pressure to build. Motor will stop when tank pressure reaches "cut-out" pressure.

2.Pull the regulator knob out and turn clockwise to increase pressure. When the desired pressure is reached push knob in to lock in place. The compressor is ready for use.

NOTE: Always operate the air compressor in well-ventilated areas free of gasoline or other combustible vapors. If the compressor is being used to operate a sprayer DO NOT place near the spray area.

D28409

14- ENG

Image 14
Contents AIR Compressor Table of Contents Important Safety Instructions Specification ChartSafety Guidelines Definitions Hazard What Could HappenWhat can Happen Hazard Never operate the compressor with Belt can cause serious injury if theyHazard Glossary AccessoriesAccessories Duty CycleGrounding Instructions InstallationLocation of the Air Compressor Risk of Electrical Extension Cords Voltage and Circuit ProtectionDescription of Operation OperationKnow Your Air Compressor Air Compressor Pump not shown How to StopBefore First Start-up How to Start Before Each Start-UpCustomer Responsibilities MaintenanceTo Check Safety Valve To Drain TankOutlet Tube Nut Pressure Relief Tube Check Valve Service and AdjustmentsTo Replace or Clean Check Valve Screwdriver Open position nothing is visibleNipple To Replace RegulatorOutlet Pressure Gauge Regulator Quick Connect Regulator ArrowStorage Troubleshooting Problem Cause CorrectionPressure reading Problem Cause Correction AIR Compressor Diagram Air Compressor Model NumberParts List KEY Part Number DescriptionPump Diagram Not Illustrated Garantía Completa POR UN AÑO Compresor DE Aire ContenidoGarantía Sears, Roebuck and Co., Dept WA, Hoffman Estates, ILResultar en lesiones menores o Definiciones DE Normas DE SeguridadModelo Nº 919-167362 ModeradasInstrucciones Importantes DE Seguridad Guarde Estas InstruccionesAgregados Y Accesorios D28409 30- SP Riesgo DE Caida Advertencia Riesgo DE Quemaduras ¿QUÉ Puede OCURRIR?Advertencia Riesgo DE Operación Insegura ¿QUÉ Puede OCURRIR? Ciclo DE Servicio GlosarioAccesorios AccesoriosUbicación del compresor de aire InstalaciónCómo Preparar LA Unidad Instrucciones Para Conectar a TierraCables de extensión eléctrica Protección del voltaje y del circuitoDescripción de operaciones OperaciónConozca su compresor de aire Antes de poner en marcha Cómo utilizar su unidadCómo detenerla Antes de cada puesta en marcha Cómo poner en marchaCómo verificar la válvula de seguridad MantenimientoResponsabilidades del cliente Cómo drenar el tanqueTubo de salida Tuerca Servicio Y AjustesPara reemplazar o limpiar la válvula Reguladora Tubo aliviador de presiónNiple Para reemplazar el reguladorRegulador Conector rápido Regulador FlechaAlmacenaje Guía DE Diagnóstico DE Problemas Problema Causa CorrecciónDesciende cuando El motor no funciona D28409 46- SP 47- SP D28409 Canada MY-HOMESears Parts and Repair Center SU-HOGARSM