SPECIFICATION CHART

Model No.

919-167362

Max. Developed HP

3

Bore

2.375"

Stroke

1.35"

Voltage-Single Phase

120V

Minimum Branch Circuit Requirement

15 amps

Fuse Type

Time Delay

Air Tank Capacity

4

Approx. Cut-In

120

Approx. Cut-out

150

SCFM @ 40 psig

8.0

SCFM @ 90 psig

5.7

SAFETY GUIDELINES - DEFINITIONS

This manual contains information that is important for you to know and understand. This information relates to protecting YOUR SAFETY and PREVENTING EQUIPMENT PROBLEMS. To help you recognize this information, we use the symbols below. Please read the manual and pay attention to these sections.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indicates an

 

 

 

 

 

 

 

Indicates a potentially

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

imminently hazardous

 

 

 

 

 

 

 

hazardous situation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

situation which, if not avoided, will

 

 

which, if not avoided, may result in

 

 

result in death or serious injury.

 

 

minor or moderate injury.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indicates a potentially

 

 

 

 

 

 

 

 

Used without the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

hazardous situation

 

 

 

 

 

 

 

 

safety alert symbol

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

which, if not avoided, could result in

 

 

 

indicates a potentially hazardous

 

 

death or serious injury.

 

 

 

situation which, if not avoided, may

 

 

 

 

 

 

 

 

 

 

 

result in property damage.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IMPORTANT SAFETY INSTRUCTIONS

SAVE THESE INSTRUCTIONS

IMPROPER OPERATION OR MAINTENANCE OF THIS PRODUCT COULD RESULT IN SERIOUS INJURY AND PROPERTY DAMAGE. READ AND UNDERSTAND ALL WARNINGS AND OPERATING INSTRUCTIONS BEFORE USING THIS EQUIPMENT.

Some dust created by power sanding, sawing, grinding, drilling, and other construction activities contains chemicals known (to the State of California) to

cause cancer, birth defects or other reproductive harm. Some example of these chemicals are:

lead from lead-based paints

crystalline silica from bricks and cement and other masonry products

arsenic and chromium from chemically-treated lumber

Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, always wear MSHA/NIOSH approved, properly fitting face mask or respirator when using such tools.

When using air tools, basic safety precautions should always be followed to reduce the risk of of personal injury.

3- ENG

D28409

Image 3
Contents AIR Compressor Table of Contents Specification Chart Safety Guidelines DefinitionsImportant Safety Instructions What Could Happen HazardWhat can Happen Hazard Belt can cause serious injury if they Never operate the compressor withHazard Duty Cycle AccessoriesAccessories GlossaryRisk of Electrical InstallationLocation of the Air Compressor Grounding InstructionsVoltage and Circuit Protection Extension CordsOperation Know Your Air CompressorDescription of Operation How to Stop Before First Start-upAir Compressor Pump not shown Before Each Start-Up How to StartTo Drain Tank MaintenanceTo Check Safety Valve Customer ResponsibilitiesScrewdriver Open position nothing is visible Service and AdjustmentsTo Replace or Clean Check Valve Outlet Tube Nut Pressure Relief Tube Check ValveRegulator Arrow To Replace RegulatorOutlet Pressure Gauge Regulator Quick Connect NippleStorage Problem Cause Correction TroubleshootingPressure reading Problem Cause Correction Air Compressor Model Number AIR Compressor DiagramKEY Part Number Description Parts ListPump Diagram Not Illustrated Sears, Roebuck and Co., Dept WA, Hoffman Estates, IL ContenidoGarantía Garantía Completa POR UN AÑO Compresor DE AireModeradas Definiciones DE Normas DE SeguridadModelo Nº 919-167362 Resultar en lesiones menores oGuarde Estas Instrucciones Instrucciones Importantes DE SeguridadAgregados Y Accesorios D28409 30- SP Advertencia Riesgo DE Quemaduras ¿QUÉ Puede OCURRIR? Riesgo DE CaidaAdvertencia Riesgo DE Operación Insegura ¿QUÉ Puede OCURRIR? Accesorios GlosarioAccesorios Ciclo DE ServicioInstrucciones Para Conectar a Tierra InstalaciónCómo Preparar LA Unidad Ubicación del compresor de aireProtección del voltaje y del circuito Cables de extensión eléctricaOperación Conozca su compresor de aireDescripción de operaciones Cómo utilizar su unidad Cómo detenerlaAntes de poner en marcha Cómo poner en marcha Antes de cada puesta en marchaCómo drenar el tanque MantenimientoResponsabilidades del cliente Cómo verificar la válvula de seguridadTubo aliviador de presión Servicio Y AjustesPara reemplazar o limpiar la válvula Reguladora Tubo de salida TuercaRegulador Flecha Para reemplazar el reguladorRegulador Conector rápido NipleAlmacenaje Problema Causa Corrección Guía DE Diagnóstico DE ProblemasDesciende cuando El motor no funciona D28409 46- SP 47- SP D28409 SU-HOGARSM MY-HOMESears Parts and Repair Center Canada