ELECTRICAL DATA

Wire Size

Use ONLY wiring size recommended for

 

single outlet branch circuit.

Fuse/Circuit

Use ONLY type and size fuse or HACR

Breaker

circuit breaker indicated on unit’s rating

 

plate. Proper current protection to the unit

 

is the responsibility of the owner.

Grounding

Unit MUST be grounded from branch

 

circuit through service cord to unit, or

 

through separate ground wire provided on

 

permanently connected units. Be sure that

 

branch circuit or general purpose outlet is

 

grounded.

Receptacle

The field supplied outlet must match plug on

 

service cord and be within reach of service

 

cord. Do NOT alter the service cord or plug.

 

Do NOT use an extension cord. Refer to

 

the table above for proper receptacle and

 

fuse type.

ELECTRIC SHOCK HAZARD.

Turn off electric power before service or installation.

All electrical connections and wiring MUST be installed by a qualified electrician and conform to the National Electrical Code and all local codes which have jurisdiction.

Failure to do so can result in property damage, personal injury and/or death.

The consumer - through the AHAM Room Air Conditioner Certification Program - can be certain that the AHAM Certification Seal accurately states the unit’s cooling and heating capacity rating, the amperes and the energy efficiency ratio.

8

Image 8
Contents 2007 Table of Contents Introduction Typical Unit ComponentsRoom AIR Conditioners Limited Warranty Routine Maintenance 08 L 1 Unit IdentificationPerformancedata Electrical Data ReceptacleFunctional Component Definitions Electronic ControlsTesting the Electronic Control XQ/WS Boards & QME Boards Testing the Electronic Control Error Code ListingsRefrigeration System Sequence of Operation Sealed Refrigeration System RepairsHermetic Component Replacement Specialprocedureinthecaseofcompressor Motor BurnoutRotarycompressorspecialtroubleshooting and Service Equipment RequiredRefrigerant Charging Method of ChargingUndercharged Refrigerant Systems Overcharged Refrigerant SystemsRestricted Refrigerant System Normal Function of Valve Malfunction of ValveCooling only Room AIR Conditioners Troubleshooting Tips Problem Possible Cause ActionReplace fuse, reset breaker. If repeats, check To equalize before attempting to restart. Instruct Vents on applicable models are in the closed Heat / Cool Room AIR Conditioners Troubleshooting Tips Troubleshooting Chart Cooling Refrigerant System Diagnosis HeatingTroubleshooting Chart Heating Electrical Troubleshooting Chart Heat PumpSystem Cools When Heating is Desired YESModels RM18L30-A, KM18L30-A, KM21L30-A, RM24L30-A, KM24L30-A SS16L30-A/B, SM18L30-A/B, SM21L30-A/B, SM24L30-A/B Model SL28L30-A SL36L30-B EQ08L11-A ES12L33-A, ES16L33-A, EM18L34-A, EM24L35-A EL36L35-A YS09L10-A, YS09L10-B YS13L33-A, YM18L34-A YL24L35-A RAC-Svc-07