Baldor MN806 manual Control Type Power Cell Replacement SCR AMP NON UL MAX Size, CAT. no, CT2

Page 10

6 Power Cells and SCRs

 

CONTROL TYPE

 

POWER CELL

REPLACEMENT SCR

AMP

 

NON UL

MAX

 

 

 

SIZE

G and R

M

VAC

 

CAT. NO.

CAT. NO.

8, 16

0, 1

A, B

460

 

SCR0005

 

 

 

575

 

SCR0010

30

20

C

466

 

SCR0015

575

 

SCR0020

 

 

 

 

55

3

D

460

 

PC1B

SCR0025(3)

575

 

PC1B

SCR0025(3)

 

 

 

 

80

E

460

 

PC2B

SCR0130(3)

575

 

PC2B

SCR130(3)

 

 

 

 

135

4

F

460

 

PC4A

SCR0055(2)

575

 

PC4B

SCR0060(2)

 

 

 

 

250

5

G

460

 

PC4A

SCR0065(2)

575

 

PC4B

SCR0070(2)

 

 

 

 

400

6

H

460

 

PC7B

SCR0095(2)

575

 

PC7B

SCR0095(2)

 

 

 

 

700

7

J

460

 

PC7B

SCR0095(2)

575

 

PC7B

SCR0095(2)

 

 

 

 

H MOVs

There are only two types of MOVs depending upon the voltage rating of the control.

208 - 460VAC 50 - 60Hz

-

MOV505EL

575VAC 60Hz

-

MOV620EL

J CT (Current Transformers)

There are two CT’s on some controls; a small one – CT1, and a larger doughnut type – CT2.

CT1 - CT6K1 (used on G and R sizes 3-7, M sizes D - J).

CT 2

G and R

M

CT2

4, 5, 6

F, G, H

CTX0025

7

J

CTX 0020

G-4

Image 10
Contents Solid State Starter Parts Table of Contents Old Style New StyleBraking Module Control Transformer Replacement SCRs/Diode and power cellsOld Style Non UL Spare Parts Size 0, 1 Size 3, 4 FusesModule LCM MOV-All Sizes Thermostat SCR/Power CellsPart Numbering Line Load TerminalsIII Nema 3R Size Size 0 Size 4, 5, 6 CT1 CT2Sizes Part Number CAT. no Control Type Power Cell Replacement SCR AMP NON UL MAX SizeCT2 Bypass Contactors Cross Over ChartControl Transformers Size General Ramp NON UL Purpose UP/DOWN MultipurposeSize General Ramp NON UL Purpose UP/DOWN Multipurpose