Baldor MN806 manual Part Numbering, Module LCM MOV-All Sizes, Thermostat SCR/Power Cells

Page 5

DEFINITE PURPOSE

Manual: MN830.

Part Numbering

D 7 0 C A

TYPE OF CONTROL

D - Definite Purpose Control

VOLTAGE CODE

7 - 208/230/460 VAC 60 hz.

8 - 208/230/460/575 VAC 60 hz.

9 - 380/415 VAC 50 hz.

ENCLOSURE

A - Open

B - NEMA 1

C - NEMA 12/3R

P - Panel Mount

CONFIGURATION

C - Control only

AMP RATING

0 - 8 amp

1 - 16 amp

2 - 30 amp

3 - 50 amp

4 - 70 amp

5 - 135 amp

A Module (LCM)

D MOV-All Sizes

*TYPE

SIZE

AMP

60Hz

 

50Hz

I

0,1,2

8,16,30

REPLACE ENTIRE

 

UNIT

 

 

 

 

II

3,4

50,70

D8X

 

D9X

III, IV

3,4,5

50,70,

L8X

 

L9X

 

 

135

 

 

 

 

 

 

INPUT VOLTAGE

PART

208-460 VAC

MOV505EL

575 VAC

MOV620EL

 

 

E Thermostat

B SCR/Power Cell(s)

SIZE

AMP

SCR/DIODE

POWER CELL

 

SIZE

208-460VAC

575VAC

 

 

0,1

8,16

SCR0035

SCR0040

2

30

SCR0045

SCR0050

3

50

SCR0085

SCR0087

DO55B

DO55B

4

70

SCR0150

SCR0150

D080B

D080B

5

135

SCR0120

SCR0123

D160A

D160B

 

 

SCR0055

SCR0060

 

 

Top number is diode.

Requires a part (SCRKIT) for proper installation.

Complete power cell D160A.

Power cell contains SCR/Diode and heatsink for one phase. The 50 and 70 power cell contains all 3 phases.

*TYPE

SIZE

AMP

PART

III, IV

3,4,5

50,70,135

TSW0010

 

 

 

 

F Line Load Terminals

*TYPE

SIZE

AMP

PART NUMBER

I

II

3,4

50,70

TBK0155

III

3,4

50,70

TBK0155

IV

5

135

TBK0065

 

 

 

 

C Fans

G Control Terminals

*TYPE

SIZE

AMP

PART NUMBER

III

3,4

50,70

FAN0005

IV

5

135

FAN0005

 

 

 

 

*TYPE

SIZE

AMP

PART NUMBER

III

3,4

50,70

TBK0180 BLK

IV

5

135

TBK0185 END PIECE

* See page D2.

D-1

Image 5
Contents Solid State Starter Parts Table of Contents New Style Old StyleOld Style Non UL Spare Parts Size 0, 1 Size 3, 4 Replacement SCRs/Diode and power cellsBraking Module Control Transformer FusesPart Numbering Thermostat SCR/Power CellsModule LCM MOV-All Sizes Line Load TerminalsIII Nema 3R CT1 CT2 Size Size 0 Size 4, 5, 6Sizes Part Number CT2 Control Type Power Cell Replacement SCR AMP NON UL MAX SizeCAT. no Control Transformers Cross Over ChartBypass Contactors Size General Ramp NON UL Purpose UP/DOWN MultipurposeSize General Ramp NON UL Purpose UP/DOWN Multipurpose