Baldor MN806 manual Sizes Part Number

Page 9

A Control Module

The Control Module is no longer available. The Multipurpose module can be used as a replacement. For sizes 0, 1, 2 (G and R controls), a replacement control is required. For sizes 4-7 and D-J a replacement module can be used. For 60Hz applications use the MB8X, and for 50Hz applications use the MB9X. A conversion manual is included with each Multipurpose module.

B Circuit Breakers

The Circuit breakers used were Westinghouse and later on Square D. Baldor no longer stocks these breakers and we no longer have an OEM buying agreement from these manufactures. Westinghouse and Square D breakers should be locally available.

C Overload Relays

There were several brands of overload relays used in the G, R and M controls. If a new heater is required for the starter contact your team with the control size, the motor AMPS and the brand of overload that is installed.

D Relays

The plug in relays in the controls are very standard and are available locally. Baldor does stock most of the relays. It is common for relays to be added to controls by the end users.

To determine if the relays are available from Baldor. The following information is required.:

What is the coil voltage of the relay?

What is the number of pins or blades in the bottom of the relay?

Are there pins or blades coming from the bottom of the relay?

Is there a part number on the relay?

See catalog MN805.

E Fans

SIZES

 

PART NUMBER

G AND R

 

M

 

 

3, 4

 

D, E, F

Fan 0005

5, 6, 7

 

G, H, I

Fan 0010

 

 

 

 

F Current Calibrators

The G and R modules require a current calibrator. The current calibrator is nothing more than a resistor that sets the current during starting. If the user needs to change this resistor (current calibrator). Contact your team with the motor current and the control size.

G-3

Image 9
Contents Solid State Starter Parts Table of Contents New Style Old StyleOld Style Non UL Spare Parts Size 0, 1 Size 3, 4 Replacement SCRs/Diode and power cellsBraking Module Control Transformer FusesPart Numbering Thermostat SCR/Power CellsModule LCM MOV-All Sizes Line Load TerminalsIII Nema 3R CT1 CT2 Size Size 0 Size 4, 5, 6Sizes Part Number Control Type Power Cell Replacement SCR AMP NON UL MAX Size CAT. noCT2 Control Transformers Cross Over ChartBypass Contactors Size General Ramp NON UL Purpose UP/DOWN MultipurposeSize General Ramp NON UL Purpose UP/DOWN Multipurpose