Studer Innotec C 2600-24, C 1600-12 user manual Connecting Plan / Front side, Solar +

Page 9

STUDER INNOTEC

COMPACT

3.3.2Protection cover for the terminals

connections

The protection is available as an option (Order ref. CFC-01) and avoid to do wrong hazardous connection on the terminals 230Vac. It mounted with strain relief clamps for the cable.

3.4Connecting Plan / Front side

M A

Don't open before disconnect line and battery

LN O

Check battery

polarity (+/-) before connecting!

A wrong connection could damage the system.

Remote

Power sharing

.

SOLAR

Remote control

Equalize Transfer delay

Auxiliary Contact

 

16A-250Vac

AC Input

 

NPEL

Temp.

T y p :C 2600-24

N ° :

Ubat: 22-32 Vdc

Pnom: 2300 VA

Uin: 150 - 250 Vac

Uout: 230 V/50 Hz I Solar: 30A max. I Charge: 70A

AC Output

L

PE

N

B

C

D

E

F

G

H

J

K

A

Battery +/-

 

 

 

Battery cable (already installed)

 

 

B

SOLAR +/-

 

 

 

Connecting terminal for Solar modules

 

C

Remote contr.

 

 

 

Connecting terminal for Remote Control RCC-01

 

D

Equalize

 

 

 

Slide switch for equalization of the Battery

 

E

Transfer delay

 

 

 

Slide switch for Transfer Delay

 

 

F

Temp.

 

 

 

Connecting terminal for Temperature sensor CT-35

 

User manual

COMPACT V4.0 E

9

Image 9
Contents Compact V4.0 E Studer InnotecSummary AssemblyGeneral Information IntroductionProgramming Maintenance EC Compliance Technical Data Compact V4.0 EGeneral Information Special Precautions Principle schematic IntroductionDescription of main functions Battery connections Place of assembly AssemblyFixing ConnectionConnecting Plan / Front side Protection cover for the terminals ConnectionsSolar + Pre-installation settings Cabling/wiringConnection to battery Connection the 230Vac-Consumer Device AC OutputConnection to Temperature Sensor Temp Connection to Remote controlConnection the 230Vac Input AC Input Connect the solar modules Solar +/- Only for solar optionDisplay and operating control elements OperatingLight Emitting Diodes Push buttonsTurning Knobs Inverter Battery ConditionCharge detection system „Standby OverloadInput current repartition Power sharing Battery chargerCycle of charge Equalization chargingCharging current Transfer systemDelayed mode of the Transfer System Fast UPS- Mode for the Transfer SwitchSolar charge controller option Set the transfer voltage thresholdMultifunctional Contact Remote ControlStandard setting Temperature sensorReset value Battery voltages and absorption timeSet the voltage and timing Threshold Programming the auxiliary contactLED11 PrincipleDisabling some of the Compact functions As per the battery capacityExamples Manual operating of Auxiliary ContactDiagram of the different modes MaintenanceModel Technical Data