www.ti.com

R25 and R28 can be changed to regulate output.

VBAT = 2.1V × [1+ R25/R28]; for bq2461x;

VBAT = 1.8V × [1+ R25/R28]; for bq2463x;

Adjust the input voltage as required. Output set to operate at 21V (bq2461x) or 18V (bq2463x) from the factory.

2 Test Summary

2.1Definitions

This procedure details how to configure the HPA422 evaluation board. On the test procedure the following naming conventions are followed. See the HPA422 schematic for details.

VXXX:

External voltage supply name (VADP, VBT, VSBT)

LOADW:

External load name (LOADR, LOADI)

V(TPyyy):

Voltage at internal test point TPyyy. For example, V(TP12) means the voltage at TP12

V(Jxx):

Voltage at jack terminal Jxx.

V(TP(XXX)):

Voltage at test point "XXX". For example, V(ACDET) means the voltage at the test

 

point which is marked as "ACDET".

V(XXX, YYY):

Voltage across point XXX and YYY.

I(JXX(YYY)):

Current going out from the YYY terminal of jack XX.

Jxx(BBB):

Terminal or pin BBB of jack xx

Jxx ON:

Internal jumper Jxx terminals are shorted

Jxx OFF:

Internal jumper Jxx terminals are open

Jxx (-YY-) ON:

Internal jumper Jxx adjacent terminals marked as "YY" are shorted

Measure:→ A,B

Check specified parameters A, B. If measured values are not within specified limits the

 

unit under test has failed.

Observe → A,B

Observe if A, B occur. If they do not occur, the unit under test has failed.

Assembly drawings have location for jumpers, test points and individual components.

2.2Equipment

2.2.1Power Supplies

Power Supply #1 (PS#1): a power supply capable of supplying 30-V at 5-A is required.

Power Supply #2 (PS#2): a power supply capable of supplying 5-V at 1-A is required.

Power Supply #3 (PS#3): a power supply capable of supplying 5-V at 1-A is required.

2.2.2LOAD #1

A 30V (or above), 5A (or above) electronic load that can operate at constant current mode

2.2.3LOAD #2

A Kepco bipolar operational power supply/amplifier, 0 ±30V (or above), 0 ±6A (or above).

2.2.4Oscilloscope

Tektronix TDS3054 scope or equivalent, 10X voltage probe.

4

bq2461x/bq2463x EVM (HPA422) Multi-Cell Synchronous Switch-Mode Charger

SLUU396A –January 2010 –Revised July 2010

Copyright © 2010, Texas Instruments Incorporated

Image 4
Contents Users Guide EVM Features General DescriptionI/O Description O Description1.4 Controls and Key Parameters Setting Controls and Key Parameters SettingRecommended Operating Conditions Recommended Operating ConditionsDefinitions EquipmentEquipment Setup MetersProcedure AC Adapter Detection ThresholdCharger Regulation Voltage Charge Current and AC Current Regultion DPMPower Path Selection Charger Cut-Off by ThermistorBill of Materials Bill of MaterialsPEC03SAAN JP1,JP3 PEC03SAAN00FEA OSTGND ACDRV,/BATDRV,/PG ACSET,CHGE ISET1,ISETBoard Layout Nd Layer Rd Layer Bottom Layer Top Assembly Bottom Assembly Top Silkscreen Bottom Silkscreen Schematics FCC Warning Evaluation Board/Kit Important NoticeEVM Warnings and Restrictions DSP Rfid