Test Summary

2.2.5METERS

Seven Fluke 75 multimeters, (equivalent or better)

Or: Four equivalent voltage meters and three equivalent current meters.

The current meters must be capable of measuring 5A+ current

2.3Equipment Setup

1.Set the power supply #1 for 0V ± 100mVDC, 5.0 ± 0.1A current limit and then turn off supply.

2.Connect the output of power supply #1 in series with a current meter (multimeter) to J1 (VIN, GND).

3.Connect a voltage meter across J1 (VIN, GND).

4.Set the power supply #2 for 0V ± 100mVDC, 1.0 ± 0.1A current limit and then turn off supply.

5.Connect the output of the power supply #2 to J4 and J5 (TS, GND).

6.Connect Load #1 in series with a current meter to J5 (SYS, GND). Turn off Load #1

7.Connect Load #2 in series with a current meter to J5 (BAT, GND). Turn off Load #2.

8.Connect a voltage meter across J5 (BAT, GND).

9.Connect an oscilloscope's probe across J5 (BAT, GND)

10.Connect a voltage meter across J5 (SYS, GND).

11.JP1 (TTC and HI): ON, JP2: ON, JP3 (VPULLUP and VREF): ON, JP4: ON, JP5: OFF.

After the above steps, the test setup for HPA422 is shown in Figure 1.

bq24610/616/617/30￿EVM

J1

HPA422

PH

Power supply￿#1

 

I

Iin

V

 

ACPWR TP1

ACPWR

PGND

TP2

J3

VCC

ACSET

ISET1

ISET2

GND

U1

JP4

APPLICATION￿CIRCUIT

TP12

SYS

J5

SYS

BAT

TP9 PGND

VBAT

Isys

 

 

I

Load

V

 

 

 

 

#1

 

 

 

 

 

I

Load

V

Ibat

 

 

#2

 

 

 

 

 

Oscilloscope

 

 

 

I

 

VREF

J2

JP3

 

VEXT

VEXT

 

 

HI

 

 

GND

 

 

L

JP1

 

TTC

O

JP2

JP5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

/ACDRV

/BATDRV

CE

PG

/STAT1

/STAT2

 

 

 

 

 

 

 

 

 

 

 

 

 

J4

PG

STAT1

VREF

TS

Power

sup ply￿#2

Figure 1. Original Test Setup for HPA422 (bq2461x/bq2463x EVM)

SLUU396A –January 2010 –Revised July 2010

bq2461x/bq2463x EVM (HPA422) Multi-Cell Synchronous Switch-Mode Charger

5

Copyright © 2010, Texas Instruments Incorporated

Image 5
Contents Users Guide General Description EVM FeaturesI/O Description O DescriptionControls and Key Parameters Setting 1.4 Controls and Key Parameters SettingRecommended Operating Conditions Recommended Operating ConditionsEquipment DefinitionsMeters Equipment SetupAC Adapter Detection Threshold ProcedureCharger Regulation Voltage Charge Current and AC Current Regultion DPMCharger Cut-Off by Thermistor Power Path SelectionBill of Materials Bill of MaterialsPEC03SAAN PEC03SAAN JP1,JP300FEA OSTACDRV,/BAT GNDDRV,/PG ACSET,CHGE ISET1,ISETBoard Layout Nd Layer Rd Layer Bottom Layer Top Assembly Bottom Assembly Top Silkscreen Bottom Silkscreen Schematics EVM Warnings and Restrictions Evaluation Board/Kit Important NoticeFCC Warning Rfid DSP