Texas Instruments BQ2463X EVM, BQ2461X manual Procedure, AC Adapter Detection Threshold

Page 6

Test Summary

www.ti.com

2.4Procedure

2.4.1AC Adapter Detection Threshold

1.Make sure EQUIPMENT SETUP steps are followed. Turn on PS#2.

2.Turn on PS#1

Measure → V(J5(SYS)) = 0 ± 500mV Measure → V(TP(VREF)) = 0V ± 1000mV Measure → V(TP(REGN)) = 0V ± 500mV

3.Increase the output voltage on PS#1 until D5 (PG) on but do not exceed 5V. Set the power supply #2 to 1.8V ± 100mVDC

Measure → V(J1(VIN)) = 4.5V ± 0.5V Measure → V(J5(SYS)) = 4.5V ± 0.5V Measure → V(TP(VREF)) = 3.3V ± 200mV Measure → V(TP(REGN)) = 0V ± 500mV Measure → D4 (/ACDRV) on, D5 (PG) on

2.4.2Charger Regulation Voltage

1.Increase the voltage of PS#1 until V(J1(VIN)) = 24V ± 0.1V. Measure → V(J5(BAT, GND)) = 0V ± 1V

2.Put JP5 on (Enable the charging). Observe → D3 (CE) on.

Measure → Peak V(J5(BAT)) = 21.0V ± 1V (bq2461x) Peak V(J5(BAT)) = 18.0V ± 1V (bq2463x)

Measure → V(TP(REGN)) = 6V ± 500mV

2.4.3Charge Current and AC Current Regultion (DPM)

1.Take off JP5 (Disable the charging).

2.Connect the Load #2 in series with a current meter (multimeter) to J5 (BAT, GND). Make sure a voltage meter is connected across J5 (BAT, GND). Turn on the Load #2. Set the output voltage to 12V (bq2461x) or 2V (bq2463x).

3.Connect the output of the Load #1 in series with a current meter (multimeter) to J5 (SYS, GND). Make sure a voltage meter is connected across J5 (SYS, GND). Turn on the power of the Load #1. Set the load current to 3.0A ± 50mA but disable the load #1. The setup is now like Figure 1 for HPA422. Make sure Ibat = 0A ± 10mA and Isys = 0A ± 10mA.

4.Put JP5 on (Enable the charging). Observe → D3 (CE) on

Measure → Ibat = 300mA ± 200mA (bq2461x) Ibat = 125mA ± 60mA (bq2463x)

Observe → D7 (STAT1) on; D8 (STAT2) off.

5.Set the Load #2 output voltage to 16.5V. Measure → Ibat = 3000mA ± 300mA Observe → D7 (STAT1) on; D8 (STAT2) off.

6.Enable the output of the Load #1

Measure → Isys = 3000mA ± 200mA, Ibat = 1400mA ± 500mA, Iin = 4000mA ± 500mA

7.Turn off the Load #1.

Measure → Isys = 0 ± 100mA, Ibat = 3000mA ± 300mA.

8.Increase the Load #2 output voltage from 16.5V to 22V (61x) or 19V (63x). Measure → Isys = 0 ± 100mA, Ibat = 0mA ± 100mA.

Observe → D7 (STAT1) off; D8 (STAT2) on.

9.Decrease the Load #2 output voltage back to 16.5V. Observe → D7 (STAT1) on; D8 (STAT2) off.

6

bq2461x/bq2463x EVM (HPA422) Multi-Cell Synchronous Switch-Mode Charger

SLUU396A –January 2010 –Revised July 2010

Copyright © 2010, Texas Instruments Incorporated

Image 6
Contents Users Guide I/O Description EVM FeaturesGeneral Description O DescriptionRecommended Operating Conditions 1.4 Controls and Key Parameters SettingControls and Key Parameters Setting Recommended Operating ConditionsDefinitions EquipmentEquipment Setup MetersCharger Regulation Voltage ProcedureAC Adapter Detection Threshold Charge Current and AC Current Regultion DPMPower Path Selection Charger Cut-Off by ThermistorBill of Materials Bill of Materials00FEA PEC03SAAN JP1,JP3PEC03SAAN OSTDRV,/PG GNDACDRV,/BAT ACSET,CHGE ISET1,ISETBoard Layout Nd Layer Rd Layer Bottom Layer Top Assembly Bottom Assembly Top Silkscreen Bottom Silkscreen Schematics Evaluation Board/Kit Important Notice FCC WarningEVM Warnings and Restrictions DSP Rfid