System Adjustments
To adjust any of the unit’s preset parameters (factory/default settings are highlighted in dark blue in each function box) the unit must be in STOP mode! Select the function you wish to change from the list of light blue boxes below. Select the parameter in the box you wish to change. For example, if you wish to switch the power saver function off, you find that the power saver function is attached to Fn02 (function 2) and that selection 2 means “off”. To select this desired option go to the main key pad on the front of the unit. Push the pad marked FUNC (function) for 2 seconds and use up/down keys to scroll through the functions. (The display will show Fn00 up to Fn09.) Stop at the function you require. (For power saver stop at Fn02.) With Fn02 on the screen push ENT (”enter”) on the keypad and use the up/down arrows to select the parameter required. The display will show from 00 to 06 (depending on which parameter you wish to change). Then select the parameter number you wish (in this case the power saver off function which is 2), by using the up/down keys and push the ENT key to enter that selection. After the selection has been made the display will show End and this will complete the parameter change. Then press DSPL to return to the function heading (one level upwards). Either continue to adjusting the next function or press DSPL again to return to the voltage display mode. The unit will also automatically return to the voltage display after about 20 seconds if left alone. Don’t forget to return to RUN mode!
Fn00 | Fn01 | Fn02 | Fn03 | Fn04 | Fn05 | Fn06 | Fn07 | Fn08 | Fno9 |
Battery type
0= Open lead acid
1= Gel ( exide ) setting
2= Gel u.s.a setting
3= Agm sealed
inverter voltage
0)200 v 50 hz
1)220 v 50 hz
2)230 v 50 hz
3)240 v 50 hz
power saver mode
1)power saver on
2)power saver off
DSPL | FUNC |
ENT | AUX |
screen example Fn09
low voltage cut out
0)10.0 v
1)10.5 v
2)11.0 v
3)11.5 v
4)12.0 v
solor charger
1)on
2)off
charging current reduction
0)25% reduction
1)50% reduction
2)75% reduction
3)full current
aux 1 setup
aux 2 setup
system fuctions
input current limit setup
0) on when charger on |
0) on when charger on
0) all functions normal
0) 25 % power 4 amps |
1) on when charger off |
1) on when charger off
1) inverter off, charger and bypass on
1) 50% power 7 amps |
2) on when inverter on |
2) on when inverter on
2)charger and bypass off, inverter on
2) 75% power 11 amps |
3) on when inverter off |
3) on when inverter off
3) inverter and charger off, bypass on
3) 100% power 15 amps |