Sterling Power Products DAI-1500C-24xx, DAI-3000C-24xx, DAI-3000C-12xx, DAI-1500C-12xx Dspl

Page 17

System Adjustments

To adjust any of the unit’s preset parameters (factory/default settings are highlighted in dark blue in each function box) the unit must be in STOP mode! Select the function you wish to change from the list of light blue boxes below. Select the parameter in the box you wish to change. For example, if you wish to switch the power saver function off, you find that the power saver function is attached to Fn02 (function 2) and that selection 2 means “off”. To select this desired option go to the main key pad on the front of the unit. Push the pad marked FUNC (function) for 2 seconds and use up/down keys to scroll through the functions. (The display will show Fn00 up to Fn09.) Stop at the function you require. (For power saver stop at Fn02.) With Fn02 on the screen push ENT (”enter”) on the keypad and use the up/down arrows to select the parameter required. The display will show from 00 to 06 (depending on which parameter you wish to change). Then select the parameter number you wish (in this case the power saver off function which is 2), by using the up/down keys and push the ENT key to enter that selection. After the selection has been made the display will show End and this will complete the parameter change. Then press DSPL to return to the function heading (one level upwards). Either continue to adjusting the next function or press DSPL again to return to the voltage display mode. The unit will also automatically return to the voltage display after about 20 seconds if left alone. Don’t forget to return to RUN mode!

Fn00

Fn01

Fn02

Fn03

Fn04

Fn05

Fn06

Fn07

Fn08

Fno9

Battery type

0= Open lead acid

1= Gel ( exide ) setting

2= Gel u.s.a setting

3= Agm sealed

inverter voltage

0)200 v 50 hz

1)220 v 50 hz

2)230 v 50 hz

3)240 v 50 hz

power saver mode

1)power saver on

2)power saver off

DSPL

FUNC

ENT

AUX

screen example Fn09

low voltage cut out

0)10.0 v

1)10.5 v

2)11.0 v

3)11.5 v

4)12.0 v

solor charger

1)on

2)off

charging current reduction

0)25% reduction

1)50% reduction

2)75% reduction

3)full current

aux 1 setup

aux 2 setup

system fuctions

input current limit setup

0) on when charger on

0) on when charger on

0) all functions normal

0) 25 % power 4 amps

1) on when charger off

1) on when charger off

1) inverter off, charger and bypass on

1) 50% power 7 amps

2) on when inverter on

2) on when inverter on

2)charger and bypass off, inverter on

2) 75% power 11 amps

3) on when inverter off

3) on when inverter off

3) inverter and charger off, bypass on

3) 100% power 15 amps

Image 17
Contents Sterling Content INVERTER: Operating instructions General InformationSterling Warranty Terms and Conditions WarrantySpecial Precautions Bypass switch Basic schematicIntroduction InverterRemote control Battery chargerBattery connections Solar charge regulator opetionalParallel Connection Series Connection Parallel-Series Connection Rear Panel InstallationLocation Connection to battery Cabling / wiringConnection to the AC Output Connection to the AC InputConnection to Aux1 & AUX2 Connection to Remote control unit optionalConnect the Solar modules Solar in + Push buttons OperatingFront Panel Display And Operating Description LED Indicator Power Dspl Overheating Over Temp Power saving function Fn02Overload Battery Condition Disabling Functions Fn05 Diagram of the different mode Charger Information Input current repartition Power sharing Fn06Charging Cycle Set the charging current Fn07Solar charge regulator Transfer systemTemperature sensor Remote control unitAuxiliary Contacts Maximum Contact load -230Vac / 5Amp-30Vdc/7AmpExample Auxiliary contact as generator starter Programming Aux Contacts AUX1, AUX2Principle Maintenance Inverter Section Specifications