E.7.5 Battery Condition

Deep discharging of batteries leads to high losses in capacity and early aging. That is why the unit will constantly monitor the battery condition. When battery voltage gets too low the Invertek switches OFF. The multi-display will show

” or ”” (Low voltage cut out P-12) the “RUN/STOP” LED RED blinks. When the battery voltage returns to 12.1V resp..24.2V, the inverter switches ON automatically. One minute before the Inverter switches OFF due to low voltage a buzzer will be heard.

The low voltage is set to 11.8V resp. 23.6V. These settings are standard for most batteries. The voltage levels are maintained by the built-in Battery-Management-System of the Invertek which looks at the load and battery condition and adjusts to suit.

This setting is comparable with the levels of 10.8V resp. 21.6V, which are given for most batteries on nominal load.

Absorption Stage

Equalization Charging

Image 19
Contents Sterling Content INVERTER: Operating instructions General InformationSterling Warranty Terms and Conditions WarrantySpecial Precautions Inverter Basic schematicBypass switch IntroductionSolar charge regulator opetional Battery chargerRemote control Battery connectionsParallel Connection Series Connection Parallel-Series Connection Location InstallationRear Panel Connection to the AC Input Cabling / wiringConnection to battery Connection to the AC OutputConnect the Solar modules Solar in + Connection to Remote control unit optionalConnection to Aux1 & AUX2 Front Panel Display And Operating Description OperatingPush buttons LED Indicator Power Dspl Overload Power saving function Fn02Overheating Over Temp Battery Condition Disabling Functions Fn05 Diagram of the different mode Set the charging current Fn07 Input current repartition Power sharing Fn06Charger Information Charging CycleSolar charge regulator Transfer systemMaximum Contact load -230Vac / 5Amp-30Vdc/7Amp Remote control unitTemperature sensor Auxiliary ContactsPrinciple Programming Aux Contacts AUX1, AUX2Example Auxiliary contact as generator starter Maintenance Inverter Section Specifications