Sterling Power Products DAI-1500C-12xx, DAI-3000C-24xx user manual Specifications, Inverter Section

Page 27

-24-

N. Specifications

MODEL

DAI-1500C-12xx

 

DAI-3000C-12xx

 

 

DAI-1500C-24xx

 

DAI-3000C-24xx

1.

Inverter Section

 

 

 

Nominal battery voltage

12V / 24V

 

12V / 24V

Input voltage range

9.5-16V / 19-32V

 

9.5-16V / 19-32V

Output voltage

200~240Vac

/ 100~120Vac

Output frequency

 

50Hz / 60Hz

Total Harmonic Distortion output THD

 

< 2%

Dynamic behavior 0→100%

 

0.5 ms

Nominal power (W)

1500W

 

3000W

Maximum power 30 min (W)

1700W

 

3500W

Maximum power 3 min (W)

2300W

 

4500W

Maximum power 5 sec (W)

3000W

 

6000W

Maximum load

Up to

short circuit

Asymmetrical load max.

Up to nominal output power

Overload and short circuit protection

Automatic disconnection with 5 time restart attempt

Overheating temperature protection

Acoustic warning before shut-off. Automatic restart

Power factor range

 

0.1-1

Power saving function

(disable / enable)

Maximum efficiency

 

85-90%

2.

Battery Charger Section

 

 

 

Maximum input voltage

265 Vac, 350 V peak

Minimum input voltage

Adjustable 150-230Vac

Input Frequency range

 

45~63Hz

Charging current adjustable

0-50A / 0-35A

 

100A / 0-70A

Setting of AC INPUT current POWER

 

0

to 15A

SHARING

 

 

 

3. Solar Charge Regulator-Floating

 

 

 

Maximum Poen Circuit Voltage

25V

 

45V

Maximum charging current

30A

 

30A

4. Battery Charge Montitoring (25)

 

 

 

*Low battery disconnection voltage

10.8V / 21.6V

*Low voltage

10.8V~12.0V (11.6V) / 21.6V~24.0V (23.2V)

*End of charge cycle voltage

14.2V~15.0V (14.4V) / 28.4V~30.0V (28.8V )

*Equalization voltage every 25 cycles

15.1V~15.5V (15.3V) / 30.2V~31.8V (30.6V)

*Floating voltage

13.3V~13.7V (13.5V) / 26.6V~27.4V (27.0V)

*Absorption charge time

 

0~4h (2h)

Temperature compensation (Option)

3mV / cell

 

 

 

 

 

5.

General date

 

 

 

AC By pass time (UPS-Mode)

 

20ms max

Potential free Multifunction contact

5A-250Vac / 7A-60V dc x 2

Max Current at Transfer relay

30A / AC 220V

 

60A / AC220V

Operating temperature

-20to +55

 

 

Fan forced ventilation

From 45/ over 75will be trip

 

 

 

 

Protection index IP

 

 

IP20

Weight

15kg

 

22kg

Dimension H*W*L (mm)

350x285x185

 

510x285x185

Remark* ( ) Factory settings

Image 27
Contents Sterling Content INVERTER: Operating instructions General InformationSterling Warranty Terms and Conditions WarrantySpecial Precautions Inverter Basic schematicBypass switch IntroductionSolar charge regulator opetional Battery chargerRemote control Battery connectionsParallel Connection Series Connection Parallel-Series Connection Installation LocationRear Panel Connection to the AC Input Cabling / wiringConnection to battery Connection to the AC OutputConnection to Remote control unit optional Connect the Solar modules Solar in +Connection to Aux1 & AUX2 Operating Front Panel Display And Operating DescriptionPush buttons LED Indicator Power Dspl Power saving function Fn02 OverloadOverheating Over Temp Battery Condition Disabling Functions Fn05 Diagram of the different mode Set the charging current Fn07 Input current repartition Power sharing Fn06Charger Information Charging CycleSolar charge regulator Transfer systemMaximum Contact load -230Vac / 5Amp-30Vdc/7Amp Remote control unitTemperature sensor Auxiliary ContactsProgramming Aux Contacts AUX1, AUX2 PrincipleExample Auxiliary contact as generator starter Maintenance Inverter Section Specifications