FB1 Input Parameters

Declaration

 

Data Type

 

Description

 

 

 

 

 

 

 

 

 

 

Address of the control byte in the SIMATIC VS120 interface that is entered under the Connection Control.

This parameter has to be wired.

Address of the status byte of the SIMATIC VS120 interface that is entered under Connection Control

Start address of the user data interface "Send“ of the

SIMATIC VS120/"Receive“ of the PLC

Start address of the user data interface "Receive“ of the SIMATIC VS120/ "Send“ of the PLC

Model number 1 to 15.

Note: For model changes, the DISA bit has to be set

Disable: disables manual key operation

Reset: Reset error evaluation device or FB error.

Note: Works also without setting the DISA bit

Trigger: Image pickup and starting the evaluation

Delay time: transfer of the trigger delay time to the

SIMATIC VS120 in us (value range: 0 to 9.999.999us).

Note:

The delay value is a multiple of 50us with rounding off limits of 0us or 50us. For example, 49us becomes 0us, 65us becomes 50us..

Receive: Receive area for the result values Permissible are only data block areas and the data type BYTE. This parameter has to be wired and the data block has to be at least as large as the maximum result to be expected.

Notes

____________________________________________________________________________

____________________________________________________________________________

____________________________________________________________________________

____________________________________________________________________________

____________________________________________________________________________

____________________________________________________________________________

TIA Training Document

Page 26 of 47

Module

E12

 

 

Status: 01/2010

Vision Sensor Shape Check with SIMATIC S7-300F 2PN/DP and VS120

Image 26
Contents Module E12 Industry Automation and Drive Technologies SCEIndustry Automation and Drive Technologies SCE Fehler! Textmarke nicht definiert Page Objective PrerequisitesStep Ethernet ConnectionProduct Description Recognizing and localizing parts Result output by meansRecognition principles of edges Checking a model for completenessConveyor Conveying Direction Main Menu Press ESCPress OK to get to the main menu Industry Automation and Drive Technologies SCE Connect Menu Data structure looks like this DB10Page Industry Automation and Drive Technologies SCE Page Industry Automation and Drive Technologies SCE Industry Automation and Drive Technologies SCE Value range for the subnet screen form Industry Automation and Drive Technologies SCE MAC addressValue range for the IP address Value range for the address of the gateway routerIndustry Automation and Drive Technologies SCE Industry Automation and Drive Technologies SCE Industry Automation and Drive Technologies SCE Industry Automation and Drive Technologies SCE Page Industry Automation and Drive Technologies SCE Function Block FB1 Tasks of FB1Page Page Triggering ResetTransmitting Delay Time Reading and transmitting result dataError information Data Block DB10 Tasks of DB10DB10 has a size of 246 bytes and can accommodate 16 SubROIs 10 FC10 Control Program Industry Automation and Drive Technologies SCE We now can load the program into the CPU Setting Up and Evaluating the Model WEB Server Based Operator Interface of VS120Page Industry Automation and Drive Technologies SCE Industry Automation and Drive Technologies SCE Industry Automation and Drive Technologies SCE Industry Automation and Drive Technologies SCE Industry Automation and Drive Technologies SCE Industry Automation and Drive Technologies SCE Page Page Industry Automation and Drive Technologies SCE Industry Automation and Drive Technologies SCE Results of Image Evaluation in the CPU Web View of the Evaluation DB10 Data View