"Connect" Menu:
The Ethernet IP mode has to be set to PNIO.
Place the cursor in front of Ports and press the OK button
Place the cursor in front of Ethernet and press the OK button
Place the cursor in front of IP Mode and press the OK button
Place the cursor in front of PNIO and press the OK button
The evaluation device now requests a restart; press the OK button to confirm.
After the restart, the red bus error LED (BF) flashes until communication is established by means of PROFINET between a controller and the VS120.
ESC may have to be pressed several times to get to the main menu.
All additional information for operating the evaluation device is provided in chapters 8.3, 8.4 and 9.2 of the operating instructions
“Image Processing Systems Vision Sensor SIMATIC VS120“.