Fusion L702B operating instructions Cycle

Page 11

CYCLE

The cycle mode allows the user to both charge and discharge a battery a number of times, in order to bring it back to peak performance.

Dependant on the final charge state required, you have the options to discharge then charge (D>C) or charge then discharge (C>D) the pack. In addition, the number of cycles and the delay between charging or discharging can be set.

n.b. When cycling a battery, the charger will use Automatic charge and discharge currents.

To start the Cycling you pack, hold the ‘Enter’ button down for 2 seconds.

‘MAX. CAPACITY’ – MAXIMUM CAPACITY

The maximum capacity setting is used to terminate a charge if the charger exceeds the selected percentage of the battery capacity.

‘PEAK DELAY’ – START PEAK DELAY

When charging a NiCd or NiMH type pack using delta-peak cut-off, the charger is looking for the pack voltage to peak and then drop off. However, some packs can give false peaks soon after the charge is commenced. Therefore, the start peak delay function overrides the peak detection for a selected number of minutes to stop any false peaks being detected. The default setting is 3 minutes.

‘TRI. CURRENT’ - TRICKLE CHARGE CURRENT

With NiCd and NiMH type batteries, it is recommended that the pack is trickle charged after the main charge has completed, so that the battery is kept fully charged and is ready to be used. Therefore, we suggest setting the trickle charge current to around 10% of the pack capacity.

SAFETY TIMER

The safety timer is used to terminate a charge if it is not completed within the selected time.

10

Image 11
Contents Emperor L702B Pro Contents Mode Type Spec SpecificationsGeneral Operation Output Battery ConnectionsDisplay Turning on & Setting the Input PowerCycle CD Menu StructureBattery Memory Screen Charge Rate 2C TCS Capacity 90% Lithium Functions and ParametersCUT.TEMPER. CUT-OFF Temperature Trickle Charge Rate Cut-off if maximum Time is reached NICD/NIMH Functions and ParametersCycle Charging a Lithium Pack ChargingCycle Charging a NICD/NIMH PackCycle View User Settings ScreenOther Screens Data View ScreenSystem Menu Factory SettingsBalancer View Safety Precautions Error MessagesLithium ION/POLYMER Battery Safety Warnings Page Page Rev