If the cycle function has been used (NiCd/NiMH only), then pressing the ‘Inc’ button shows the charge and discharge statistics for the previous 10 cycles.
BALANCER VIEW
When a Lithium pack is connected to the charger, the balancer screen shows the balance statistics for the pack and allows the user to read off the individual cell voltages.
Number of cells and | Press the ‘Inc’ or ‘Dec’ |
button to select a | |
total pack voltage | specific cell to view. |
Highest and lowest
voltage cells
3S=11.845V 1S=3.944V 33.95V 13.94V 8mV
0]NiMH 6S 3300mAh
CHG. | : 3.3A | 5mV/C | |
DCHG. | : | 5.0A | 0.8V/C |
CYCLE | : | CD | 1X 10m |
Voltage difference between the highest and lowest cells
SYSTEM MENU
The system menu is accessed by holding down the ‘Mode’ button and connecting the power. In this menu you can adjust the LCD parameters and set the user name that appears on the welcome screen.
Mode
Power
On
Press and hold the Mode button
whilst connecting the power.
LCD CONTRAST: | 10 |
|
| |
| LCD BACKLIT : | ON |
| |
| <www.LogicRC.com > |
| ||
| ABCDEFGHIJKLMNOPQ |
| ESC | |
| RSTUVWXYZ abcdefg |
|
| |
| hijklmnopqrstuvwx |
|
| |
| yz 0123456789 |
|
| |
|
|
|
|
|
|
|
|
|
|
Emperor L702BP v1
www.LogicRC.com
To edit the username, press the ‘Dec’ button to move down the line selection arrow to the username line. When on this line selection changes to character selection, so using the ‘Inc’ and Dec’ buttons select the character to be changed, and then press the ‘Enter’ button to highlight the character. Using the ‘Inc’ and ‘Dec’ buttons to select the new character and press the ‘Enter’ button when finished. Continue this to change each character. When you have finished, press the ‘Esc’ key to exit this menu.
FACTORY SETTINGS
To reset the charger to the original factory settings, press and hold the ‘Esc’ button when connecting the power.