Fusion L50B PRO operating instructions NiMH Mode

Page 9

If the other buttons are pressed, or nothing is pressed, the present battery type stops flashing.

If the Battery TYPE button is pressed and briefly held, the recent & previous data will be shown until the Battery TYPE button is pressed.

If the ENTER button is briefly pressed, a parameter which can be adjusted starts to flash and if the ENTER button is pressed again, the next parameter starts to flash. If nothing is pressed for 3 seconds, the parameter stops flashing.

Once the ENTER button is pressed and briefly held, the charger starts to charge according to the selected parameters.

NiMH Mode

BATT TYPE

CHARGE

INC

 

NiMH delta-peak-

 

C=3.0A

 

DEC

volt = 0mV/cell

 

ENTER

 

 

ENTER

INC

DEC

NiMH CHARGE C=3

START

BATTERY CHECK

WAIT PLEASE....

CHG 0:00 00000 NC+3.00A 5.200V

INC

DEC

NiMH delta-peak- volt =

NiMH CHARGE C=3

Setting Charge Current

Adjust the desired charge current, which ranges from 0.1A to 6.0A with the INC & DEC buttons. Press the ENTER button to confirm the setting.

NiMH delta-peak- volt =

Setting Delta Peak Sensitivity

Set the Delta Peak Sensitivity from 5mV to 25mV per cell with the INC & DEC buttons and press the ENTER button to confirm the setting.

7

Image 9
Contents Please keep for future reference TyphoonPage Special Features SpecificationsSafety Precautions Lithium ION/POLYMER Battery Safety Warnings Lithium ION/POLYMER/FE Batteries Input Power Output Battery Connections12V DC Setting Charge Current NiCd ModeSetting Delta Peak Sensitivity OperationNiMH Mode Setting Battery Capacity Setting Battery Voltages For Li-Ion Battery PackLithium Modes Li-Ion/Li-Po/Li-Fe Setting Battery Voltages For Li-Po Battery Pack Setting Battery Voltages For Li-Fe Battery PackSetting Battery Type Setting Battery Voltages For a Lead-Acid Pb Battery Pack Pb ModeDisplays During Charge Screen DisplaysCompletion Display with Audible Warning Data DisplayNo Battery Error Messages