Bryant R-410A warranty Tested combination

Page 14

*Tested combination.

In most cases, only 1 method should be used to achieve TDR function. Using more than 1 method in a system may cause degradation in performance. Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR.

Based on computer simulation. TXV must be Puron® compatible and hard shutoff type. ** Ratings shown are with R-22 TXV replaced with Puron® TXV.

EER — Energy Efficiency Ratio

SEER — Seasonal Energy Efficiency Ratio TDR Time-Delay Relay

TXV — Puron® Thermostatic Expansion Valve

NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.

2.Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for electric air conditioners. Ratings for other com- binations are determined under DOE computer simulation procedures.

3.Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.

4.Do not apply with capillary tube coils as performance and reliability are significantly affected.

— 14—

Image 14
Contents DELUXE 11 SEER AVAILABLE OPTIONS591B 60 Hz AIR CONDITIONERDIMENSIONS DIMENSIONS INCHARGING SUBCOOLING TXV-TYPE EXPANSION DEVICE RECOMMENDED TUBE DIAMETERSCHECK-FLO-RATER PISTON WHEN THE COMPLETE SYSTEM018-A SPECIFICATIONSUNIT SIZE-SERIES 024-ASPECIFICATIONS Continued ACCESSORY USAGE GUIDELINE ACCESSORY DESCRIPTION AND USAGE Listed AlphabeticallyLEVEL ACCESSORY DESCRIPTION AND USAGE Listed Alphabetically ContinuedSOUND POWER dBA A-WTD, WITHOUT PURE TONE PENALTY SIZECOMBINATION RATINGS COMBINATION RATINGS Continued COMBINATION RATINGS Continued COMBINATION RATINGS Continued COMBINATION RATINGS Continued COMBINATION RATINGS Continued Tested combination DETAILED COOLING CAPACITIES 591BN018-A Outdoor Section With CC5A/CD5AA024 Indoor Section591BN024-A Outdoor Section With CC5A/CD5AA030 Indoor Section DETAILED COOLING CAPACITIES* Continued 591BN030-A Outdoor Section With CC5A/CD5AA036 Indoor Section591BN036-A Outdoor Section With CC5A/CD5AA042 Indoor Section DETAILED COOLING CAPACITIES* Continued 591BN042-A Outdoor Section With CC5A/CD5AA048 Indoor Section 591BN048-A Outdoor Section With CC5A/CD5AA060 Indoor Section 591BN060-A Outdoor Section With CC5A/CD5AW060 Indoor Section 591BN024-A CONDENSER ONLY RATINGS591BN018-A 591BN030-A591BN042-A CONDENSER ONLY RATINGS* Continued591BN036-A 591BN048-A591BN060-A SYSTEM DESIGN SUMMARYMATCHED SYSTEM A98599Page Operating Characteristics GUIDE SPECIFICATIONSWarranty for inclusion by specifying engineer Special Features