Bryant R-410A warranty DETAILED COOLING CAPACITIES* Continued

Page 19
Manual background

DETAILED COOLING CAPACITIES* Continued

EVAP

 

 

 

 

 

CONDENSER ENTERING AIR TEMPERATURES °F

 

 

 

 

AIR

75

 

85

 

95

 

105

 

115

 

125

 

 

 

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

Capacity

Total

 

 

MBtuh†

MBtuh†

MBtuh†

MBtuh†

MBtuh†

MBtuh†

 

 

Sys

Sys

Sys

Sys

Sys

Sys

CFM

EWB

Total

Sens‡

Kw**

Total

Sens‡

Kw**

Total

Sens‡

Kw**

Total

Sens‡

Kw**

Total

Sens‡

Kw**

Total

Sens‡

Kw**

591BN036-A Outdoor Section With CC5A/CD5AA042 Indoor Section

 

 

72

42.30

21.87

 

2.99

 

40.41

 

21.15

 

3.28

38.37

 

20.38

3.62

36.15

19.55

3.98

33.63

 

18.62

 

4.36

 

30.84

17.60

 

4.77

 

 

1050

67

38.65

26.76

 

2.96

 

36.69

 

25.95

 

3.26

34.62

 

25.11

3.60

32.26

24.14

3.96

29.82

 

23.15

 

4.33

 

27.19

22.09

 

4.73

 

 

62

34.55

31.25

 

2.93

 

32.77

 

30.37

 

3.22

30.78

 

29.36

3.53

28.62

28.18

3.86

26.52

 

26.52

 

4.23

 

24.67

24.67

 

4.64

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

32.91

32.91

 

2.91

 

31.49

 

31.49

 

3.20

30.00

 

30.00

3.52

28.33

28.33

3.85

26.53

 

26.53

 

4.23

 

24.67

24.67

 

4.64

 

 

 

72

42.98

22.71

 

3.05

 

41.08

 

22.02

 

3.35

39.04

 

21.28

3.69

36.71

20.45

4.04

34.14

 

19.54

 

4.43

 

31.26

18.50

 

4.84

 

 

1200

67

39.54

28.35

 

3.02

 

37.61

 

27.61

 

3.32

35.40

 

26.76

3.65

32.99

25.83

4.01

30.43

 

24.83

 

4.41

 

27.75

23.73

 

4.82

 

 

62

35.51

33.48

 

3.00

 

33.57

 

32.47

 

3.30

31.49

 

31.49

3.61

29.61

29.61

3.95

27.80

 

27.80

 

4.33

 

25.79

25.79

 

4.75

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

34.40

34.40

 

2.99

 

32.98

 

32.98

 

3.28

31.37

 

31.37

3.60

29.62

29.62

3.95

27.81

 

27.81

 

4.33

 

25.80

25.80

 

4.75

 

 

 

72

43.46

23.44

 

3.12

 

41.56

 

22.80

 

3.42

39.45

 

22.06

3.75

37.09

21.25

4.11

34.48

 

20.36

 

4.49

 

31.55

19.31

 

4.90

 

 

1350

67

40.23

29.84

 

3.08

 

38.21

 

29.10

 

3.38

35.97

 

28.29

3.71

33.52

27.39

4.07

30.89

 

26.36

 

4.46

 

28.15

25.23

 

4.88

 

 

62

36.33

35.44

 

3.06

 

34.27

 

34.27

 

3.37

32.49

 

32.49

3.70

30.76

30.76

4.05

28.81

 

28.81

 

4.43

 

26.74

26.74

 

4.85

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

57

35.80

35.80

 

3.06

 

34.19

 

34.19

 

3.37

32.50

 

32.50

3.70

30.78

30.78

4.05

28.82

 

28.82

 

4.43

 

26.76

26.76

 

4.85

 

 

 

 

 

 

 

 

 

Multipliers for Determining the Performance With Other Indoor Sections

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Indoor

 

 

 

 

 

 

 

 

Cooling

 

 

 

 

Indoor

 

 

 

 

 

 

 

Cooling

 

 

 

 

 

 

Section

 

Size

 

 

Capacity

 

 

 

Power

 

 

Section

 

Size

 

Capacity

 

 

 

Power

 

 

 

 

COILS + 355MAV060080 VARIABLE SPEED FURNACE

 

 

CE3AA

 

036

 

 

0.98

 

 

 

0.93

 

 

 

 

CC5A/CD5AA

042

 

 

 

1.00

 

 

 

0.92

 

 

 

 

 

042

 

 

0.99

 

 

 

0.93

 

 

 

 

CC5A/CD5AW

036

 

 

 

0.99

 

 

 

0.93

 

 

 

CK3BA

 

042

 

 

1.00

 

 

 

0.92

 

 

 

 

 

CE3AA

 

036

 

 

 

0.98

 

 

 

0.93

 

 

CK5A/CK5BA

042

 

 

1.00

 

 

 

0.92

 

 

 

 

 

 

 

042

 

 

 

0.99

 

 

 

0.93

 

 

CK5A/CK5BT

042

 

 

1.00

 

 

 

0.92

 

 

 

 

 

CK3BA

 

042

 

 

 

1.00

 

 

 

0.94

 

 

CK5A/CK5BW

036

 

 

0.99

 

 

 

0.92

 

 

 

 

CK5A/CK5BA

042

 

 

 

1.00

 

 

 

0.94

 

 

 

COILS + 355MAV060120 VARIABLE SPEED FURNACE

 

 

 

CK5A/CK5BT

042

 

 

 

1.00

 

 

 

0.94

 

 

CC5A/CD5AA

042

 

 

1.00

 

 

 

0.92

 

 

 

 

CK5A/CK5BW

036

 

 

 

0.99

 

 

 

0.94

 

 

CC5A/CD5AW

036

 

 

0.99

 

 

 

0.93

 

 

 

 

 

COILS + 355MAV060100 VARIABLE SPEED FURNACE

 

 

 

 

042

 

 

0.99

 

 

 

0.92

 

 

 

 

CC5A/CD5AA

042

 

 

 

1.00

 

 

 

0.92

 

 

 

CE3AA

 

036

 

 

0.98

 

 

 

0.93

 

 

 

 

CC5A/CD5AW

036

 

 

 

0.99

 

 

 

0.93

 

 

 

 

 

042

 

 

0.99

 

 

 

0.93

 

 

 

 

 

 

 

042

 

 

 

0.99

 

 

 

0.92

 

 

CK5A/CK5BA

042

 

 

1.00

 

 

 

0.92

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CK5A/CK5BT

042

 

 

1.00

 

 

 

0.92

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CK5A/CK5BW

036

 

 

0.99

 

 

 

0.93

 

 

 

See notes on page 22.

— 19—

Image 19
Contents AIR CONDITIONER AVAILABLE OPTIONS591B 60 Hz DELUXE 11 SEERDIMENSIONS IN DIMENSIONSWHEN THE COMPLETE SYSTEM RECOMMENDED TUBE DIAMETERSCHECK-FLO-RATER PISTON CHARGING SUBCOOLING TXV-TYPE EXPANSION DEVICE024-A SPECIFICATIONSUNIT SIZE-SERIES 018-ASPECIFICATIONS Continued ACCESSORY DESCRIPTION AND USAGE Listed Alphabetically ACCESSORY USAGE GUIDELINESIZE ACCESSORY DESCRIPTION AND USAGE Listed Alphabetically ContinuedSOUND POWER dBA A-WTD, WITHOUT PURE TONE PENALTY LEVELCOMBINATION RATINGS COMBINATION RATINGS Continued COMBINATION RATINGS Continued COMBINATION RATINGS Continued COMBINATION RATINGS Continued COMBINATION RATINGS Continued Tested combination 591BN018-A Outdoor Section With CC5A/CD5AA024 Indoor Section DETAILED COOLING CAPACITIES 591BN024-A Outdoor Section With CC5A/CD5AA030 Indoor Section 591BN030-A Outdoor Section With CC5A/CD5AA036 Indoor Section DETAILED COOLING CAPACITIES* Continued591BN036-A Outdoor Section With CC5A/CD5AA042 Indoor Section 591BN036-A Outdoor Section With CC5A/CD5AA042 Indoor Section 591BN042-A Outdoor Section With CC5A/CD5AA048 Indoor Section 591BN048-A Outdoor Section With CC5A/CD5AA060 Indoor Section 591BN060-A Outdoor Section With CC5A/CD5AW060 Indoor Section 591BN030-A CONDENSER ONLY RATINGS591BN018-A 591BN024-A591BN048-A CONDENSER ONLY RATINGS* Continued591BN036-A 591BN042-ASYSTEM DESIGN SUMMARY 591BN060-AA98599 MATCHED SYSTEMPage Special Features GUIDE SPECIFICATIONSWarranty for inclusion by specifying engineer Operating Characteristics