The
2.1.8 Viewing Charge Information
Additional charge information is available any time by pressing the INFO button. This information is retained after the battery is disconnected until the next battery is connected. After 20 seconds the display returns to the default display of amps and volts per cell. The following information can be viewed:
Parameter | DISPLAY | DESCRIPTION |
Charger State | XXXXXX | Message describing charger state. |
Amps | CHARGER DC AMPS | Charger current in amps. |
| AA: xxxA |
|
Volts/Cell | BATTERY V/C | Battery voltage in volts per cell (v/c). |
| VC: x.xxVC |
|
Amp Hours | ACCUMULATED AH | Amp Hours returned for the current (or last) charge cycle. |
| AH: xxxxAH |
|
Charge Time | CHARGE TIME | Charge time for the current (or last) charge cycle in hours and minutes. |
| TC: xx:xxHM |
|
Percent Return | % AH RETURNED | Percent of Amp Hours returned as a function of battery AH rating. |
| PR: xxx% |
|
Voltage | BATTERY VOLTS | Total battery voltage in volts. |
| VV: xx.xV |
|
End Current | CHARGE END AMPS | End current for the last charge cycle (current amps if charging) |
| EA: xxxA |
|
End Voltage | CHARGE END VOLTS | End voltage for the last charge cycle (current voltage if charging) |
| EV: x.xxVC |
|
Software | SOFTWARE VERSION | Control software version |
| SW: x.xx |
|
10