lug, and the like, extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box. Whenever the adapter is used, it must be held in place with a metal screw.

NOTE: In Canada, the use of a temporary adapter is not permitted by the Canadian Electric Code.

3.Grounded, cord-connected tools intended for use on a supply circuit having a nominal rating between 150 - 250 volts, inclusive:

If the tool is intended for use on a circuit that has an outlet that looks like the one illustrated in Fig. C, the tool will have a grounding plug that looks like the plug illustrated in Fig. C. Make sure the tool is connected to an outlet having the same configuration as the plug. No adapter is available or should be used with this tool. If the tool must be re- connected for use on a different type of electric circuit, the re- connection should be made by qualified service personnel; and after re-connection, the tool should comply with all local codes and ordinances.

IN ALL CASES, MAKE CERTAIN THE RECEPTACLE IN QUESTION IS PROPERLY GROUNDED. IF YOU ARE NOT SURE HAVE A QUALIFIED ELECTRICIAN CHECK THE RECEPTACLE. NEVER REMOVE GROUNDING PRONG FROM POWER PLUG.

EXTENSION CORDS

Use proper extension cords. Make sure your extension cord is in good condition and is a 3-wire extension cord which has a 3- prong grounding type plug and matching receptacle which will accept the tool’s plug. When using an extension cord, be sure to use one heavy enough to carry the current of the tool. An undersized cord will cause a drop in line voltage, resulting in loss of power and overheating. Fig. D, shows the correct gauge to use depending on the cord length. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.

Length of Cord in Feet

 

115V

25 Ft.

50 Ft.

100 Ft.

150 Ft.

200 Ft.

250 Ft.

300 Ft.

400 Ft.

500 Ft.

 

230V

50 Ft.

100 Ft.

200 Ft.

300 Ft.

400 Ft.

500 Ft.

600 Ft.

800 Ft.

1000 Ft.

 

 

 

 

 

 

 

 

 

 

 

 

0-2

18

18

18

16

16

14

14

12

12

 

 

 

 

 

 

 

 

 

 

 

Rating

2-3

18

18

16

14

14

12

12

10

10

 

 

 

 

 

 

 

 

 

 

4-5

18

18

14

12

12

10

10

8

8

 

3-4

18

18

16

14

12

12

10

10

8

Ampere

 

 

 

 

 

 

 

 

 

 

5-6

18

16

14

12

10

10

8

8

6

 

 

 

 

 

 

 

 

 

 

 

 

 

6-8

18

16

12

10

10

8

6

6

6

Nameplate

8-10

18

14

12

10

8

8

6

6

4

 

 

 

 

 

 

 

 

 

 

10-12

16

14

10

8

8

6

6

4

4

 

 

 

 

 

 

 

 

 

 

 

 

 

12-14

16

12

10

8

6

6

6

4

2

 

14-16

16

12

10

8

6

6

4

4

2

 

 

 

 

 

 

 

 

 

 

 

 

16-18

14

12

8

8

6

4

4

2

2

 

 

 

 

 

 

 

 

 

 

 

 

18-20

14

12

8

6

6

4

4

2

2

Fig. D

3

Image 3
Contents Instruction Manual Tile Saw Grounding Instructions Safety InstructionsLength of Cord in Feet Extension CordsImportant Safety Instructions Safety Guidelines DefinitionsPage Additional Specific Safety Rules Motor Replacement PartsUnpacking AssemblyFunctional Description ForewordLocate and identify all parts AssemblyAttaching SAW ARM to the Cutting Tray Attaching the SAW Blade Starting and Stopping Machine OperationOperating Tile SAW Locking Switch OFF PositionRIP Guide MaintenanceKeep Tool Clean Water PumpBrush Inspection and Lubrication AccessoriesService and Repairs LubricationPORTER-CABLE Limited ONE Year Warranty Canadian PORTER-CABLE Delta Service Centers