Bryant 576b installation instructions Physical Data

Page 3

Table 1 — Physical Data

 

UNIT

569C072

 

569C090

 

569C120

 

 

576B090

 

576B102

 

576B120

NOMINAL CAPACITY (tons)

6

 

71/2

 

10

 

 

71/2

 

81/2

 

10

OPERATING WEIGHT (lb)

 

 

 

 

 

 

 

 

 

 

 

 

 

Aluminum Coils (Std)

340

 

392

 

426

 

 

510

 

564

 

564

 

 

 

 

 

Copper Coils (Optional)

386

 

460

 

503

 

 

578

 

632

 

632

RIGGING WEIGHT (lb)

 

 

 

 

 

 

 

 

 

 

 

 

 

Aluminum Coils (Std)

390

 

420

 

445

 

 

560

 

614

 

614

 

 

 

 

 

Copper Coils (Optional)

436

 

488

 

522

 

 

628

 

682

 

682

REFRIGERANT*

 

 

 

 

 

R-22

 

 

 

 

 

Operating Charge†

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Typical (lb)

11.4

 

13.6

 

16.5

 

 

14.3

 

16.4

 

16.4

Shipping Charge (lb)

2.0

 

2.0

 

2.0

 

 

2.0

 

2.0

 

2.0

COMPRESSOR

Reciprocating,

 

 

Scroll, Hermetic

 

 

Reciprocating, Semi-Hermetic

Hermetic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1...06DH824

Qty...Type

1...H26A72Q

 

1...ZR94KC

 

1...ZR125KC

 

 

1...06DA818

 

1...06DA824

 

 

 

 

 

 

 

(See Note)

Qty Cylinders (ea)

 

 

 

 

 

 

 

 

 

 

 

 

2

 

NA

 

NA

 

 

4

 

6

 

6

Speed (rpm)

3500

 

3500

 

3500

 

 

1750

 

1750

 

1750

Oil Charge (oz) (ea)

65

 

85

 

110

 

 

88

 

128

 

128

CONDENSER AIR FAN

 

 

 

 

 

Propeller; Direct Drive

 

 

 

 

Qty...Rpm

1...850

 

1...1100

 

1...1100

 

 

1...1100

 

1...1100

 

1...1100

 

 

 

 

 

Diameter (in.)

26

 

26

 

26

 

 

26

 

26

 

26

Motor Hp (NEMA)

1/

 

3/

4

 

3/

 

 

3/

 

3/

 

3/

Watts

 

3

 

 

 

4

 

 

4

 

4

 

4

 

444

 

976

 

960

 

 

930

 

930

 

930

Nominal Cfm Total

3800

 

6500

 

7000

 

 

6500

 

6500

 

6500

CONDENSER COIL

 

 

 

Enhanced Copper Tubes, Aluminum Lanced Fins

 

 

Rows...Fins/in.

 

 

 

 

2...17

 

 

 

 

 

 

Face Area (sq ft)

12.24

 

18.0

 

20.50

 

 

18.0

 

18.0

 

18.0

 

 

 

 

 

Storage Capacity (lb)**

11.26

 

16.56

 

18.87

 

 

16.56

 

16.56

 

16.56

CONNECTIONS (sweat)

11/8

 

11/8

 

11/8

 

 

11/8

 

11/8

 

11/8

Suction (in.)

 

 

 

 

 

 

 

 

 

 

 

Liquid (in.)

1/

 

1/

2

 

5/

 

 

1/

 

5/

 

5/

 

 

2

 

 

 

8

 

 

2

 

8

 

8

CONTROLS

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressurestat Settings (psig)

 

 

 

 

 

 

 

 

 

 

 

 

 

High

Cutout

 

 

 

 

426 ± 7

 

 

 

 

 

 

Cut-in

 

 

 

 

320 ± 20

 

 

 

 

 

Low

Cutout

 

 

 

 

7 ± 3

 

 

 

 

 

 

Cut-in

 

 

 

 

22 ± 5

 

 

 

 

 

LEGEND

NEMA — National Electrical Manufacturers Association

*Unit is factory supplied with holding charge only.

†Typical operating charge with 25 ft of interconnecting piping.

**Storage capacity of condenser coil with coil 80% full of liquid R-22 at 124 F.

NOTE: Unit 576B120 has one step of unloading. Full load is 100% of capacity, and one step of unloading is 67% capacity. Unit 576B120 has the following unloader settings: load is 70 ± 1 psig and unload is 60

± 2 psig.

3

Image 3
Contents Important Read Before Installing ContentsSafety Considerations III. Compressor Mounting InstallationLocate the Unit II. RIG and Place UnitPhysical Data Electrical Connections Dimensions ft-inService Valve Connections Weight Chart lbField Power Supply Fig Refrigerant Piping SizesLiquid Line Data Control Voltage Connections Power Wiring ConnectionsElectrical Data PRE-START-UP VI. Accessory InstallationAccessory List AccessoryCare and Maintenance START-UP START-UP and AdjustmentsCompressors Service CleaningCondenser Coil II. LubricationCompressor Removal VI. Crankcase HeaterVII. Refrigerant Charge IX. High Flow Valves VIII. Refrigerant Service PortsSymptom Cause Remedy Troubleshooting GuideCLO LPSCAP OFCIndoor Unit START-UP ChecklistOutdoor Unit ControlsIII. START-UP