Powermatic M-1791257 Converting from 230 Volt to 460 Volt Three Phase Only, Three-Phase Test Run

Page 14

Converting from 230 Volt to 460 Volt (Three Phase Only)

To convert from 230 volt to 460 volt:

1.Remove the four Phillips head screws on the switch plate (Figure 8) and tilt the switch plate down. Then remove the cover of the switch box.

2.Replace the current contactor with the 460V magnetic contactor (part no. 2013-102D for model 2013; part no. 2415-102D for model 2415; purchased separately).

3.Re-connect the motor leads according to the diagrams inside the motor junction box. These diagrams are also found on pages 56 and 57 of this manual. (Diagram in motor junction box should take priority.)

4.Change the lamp input power from 230V to 460V in the panel of the transformer (Figure 9) in accordance with the diagrams on pages 56 and 57.

5.If using a plug, install a proper UL/CSA listed plug suitable for 460V operation.

IMPORTANT: Consult the diagrams on pages 56 and 57 for clarification of any of these changes on 230V to 460V conversion.

Three-Phase Test Run

On the three-phaseunit, after wiring has been completed, you should check that the wires have been connected properly:

1.Open lower front door of the Band Saw.

2.Connect machine to power source and press the start button, shown in Figure 28, for just an instant, then press the stop button. (See “Operating Controls” on page 21 for further information on the control buttons.)

3.The lower wheel should rotate clockwise as viewed from the front of the machine. If the rotation of the lower wheel is incorrect, disconnect machine from power.

4.Switch any two of the three wires at "R,S,T" (see “Electrical Connections”, pages 56 and 57) and re-connect machine to power source.

Figure 8

Figure 9

14

Image 14
Contents 20and 24 Band Saws Warranty and Service Warranty PeriodTable of Contents Page Page Page Introduction Specifications 2013Features and Terminology Floor DiagramsContents of the Shipping Container UnpackingAssembly Installing Fence and RailsPage Grounding Instructions Dust CollectionExtension cords Volt, Single Phase OperationVolt, Three Phase Operation Converting from 230 Volt to 460 Volt Three Phase Only Three-Phase Test RunTable Stop AdjustmentsTable Tilt Installing/Changing Blades Blade TensionBlade Tracking Upper Blade Guide Assembly Upper Blade Guides and Upper Support BearingLower Blade Guides and Lower Support Bearing Miter Gauge Belt TensionBelt Alignment Blade Speed AdjustmentOperating Controls Brake Pedal General ProcedureOperation Resawing RippingCrosscutting Blade LeadBlade Selection Shape WidthPitch Set MaterialBand Wheel Replacement MaintenanceTire Replacement Blade Selection Guide For Radius CuttingTroubleshooting Operational Problems Trouble Troubleshooting Mechanical and Electrical Problems Replacement Parts Trouble Probable Cause RemedyParts List Saw Body Assembly 2013 Band Saw Index No. Part No Description Size QtyParts List Saw Body Assembly 2415 Band Saw 2415-102ORNSaw Body Assembly 2013 Parts List Table Assembly 2013 Band Saw Index No. Part No Description Size Qty Parts List Table Assembly 2415 Band Saw Index No. Part No Description Size Qty Table Assembly 2013 Parts List Upper Wheel Base Assembly 2013 Band Saw For 2013-3, serial #01062013090 toParts List Upper Wheel Base Assembly 2415 Band Saw For 2415-3, serial #01062415011 toUpper Wheel Base Assembly 2013 Parts List Lower Wheel Base Assembly 2013 Band Saw ST 18AWG Parts List Lower Wheel Base Assembly 2415 Band Saw 2013-459 Limit Switch Cord not shown Lower Wheel Base Assembly 2013 Parts List Guide Bracket Assembly 2013 Band Saw Index No. Part No Description Size Qty Parts List Guide Bracket Assembly 2415 Band Saw Index No. Part No Description Size Qty Guide Bracket Assembly 2013 Motor Band Saw onlyMagnetic Switch Electrical Connections 230 Volt, 3 Phase Models 2013 Electrical Connections 460 Volt, 3 Phase Models 2013 This page intentionally left blank This page intentionally left blank