Bryant 583B instruction manual Roof Curb Dimensions Top View

Page 3

6

C

46 3/16

B

17 3/8

D

 

TYP.

44 5/16

1 TYP.

7/8

 

 

3

 

13/16

 

SUPPORT B

B

A

 

 

SUPPORT A (2)

SIDE

2

(2)

 

END VIEW

END

(2)

DECK PAN (INSULATED)

Fig. 4—Roof Curb Dimensions

Top View

SIDE PANEL

0.75"

A99320

 

 

 

BASE PAN

 

 

 

 

 

 

 

 

 

 

4.0"

 

 

 

BOTTOM SUPPLY

3.0"

 

 

 

 

 

SUPPORT RIB(S)

SEAL STRIP

 

(FACTORY SUPPLIED)

 

COUNTER FLASHING

NAILER

(FIELD SUPPLIED)

 

ROOFING FELT

 

(FIELD SUPPLIED)

 

CANT STRIP

INSULATION

(FIELD SUPPLIED)

(FIELD SUPPLIED)

 

ROOFING MATERIAL (FIELD SUPPLIED)

Fig. 5—Roof Curb Dimensions

Side View

A99340

—3—

Image 3
Contents Rules for Safe Installation and Operation Safety ConsiderationsIII. Field Fabricate Ductwork Receiving and Installation I. Check EquipmentGeneral II. Provide Unit SupportRoof Curb Dimensions Top View VI. Connect Condensate Drain Roof Curb DimensionsIV. Provide Clearances RIG and Place UnitCharacteristics Electrical Unit Weight Unit Height Center of GravityRequired Clearance for Operation and Servicing Required Clearance to Combustible MatlNEC. Required Clearances Unit 583B Maximum Weight Size VII. Install Flue HoodIX. Install Duct Connections VIII. Install GAS PipingPhysical Data Unit 583B Install Electrical ConnectionsNominal Iron Pipe Size Internal Diameter Length of PIPE, FT† Maximum GAS Flow CapacitySpecial Procedures For 208-V Operation HIGH-VOLTAGE ConnectionsControl Voltage Connections RLA LRA FLA MCA Mocp Electrical Data 583BCheck for Refrigerant Leaks Start Up Heating Section and Make AdjustmentsPRE-START-UP START-UPBtuh Orifices Heating InputsHeating Number GAS Supply Pressure Manifold Pressure InputHeating Temperature Rise F Input Btuh Error Code LED IndicationLED Indications Start-Up Cooling Section and Make Adjustments Indoor Airflow and Airflow AdjustmentsSpeed 208/230-3-60 Wiring Diagram 460-3-60 Wiring Diagram Maintenance Air FilterEvaporator Blower and Motor Cooling Charging Chart, 583B030 Units WET Coil AIR DELIVERY* Horizontal and Downflow Discharge Blower Housing and Flue Collector Box Flue Gas PassagewaysMain Burners Limit SwitchCombustion-Air Blower Burner IgnitionEvaporator Airflow Electrical Controls and WiringPressure Switches Refrigerant CircuitLiquid Line Filter Drier Refrigerant SystemCompressor Oil Servicing Systems on Roofs with Synthetic MaterialsAIR Conditioner with Puron R-410A-QUICK Reference Guide Symptom Cause Remedy Troubleshooting CoolingWater in gas line Drain. Install drip leg Troubleshooting HeatingLED OFF LED TROUBLESHOOTING-ERROR CodePreliminary Information START-UP Checklist Remove and Store in JOB File
Related manuals
Manual 28 pages 39.19 Kb Manual 30 pages 37.07 Kb

583B specifications

The Bryant 583B is an advanced, high-efficiency gas furnace designed to provide exceptional heating performance and reliability. With a focus on comfort and energy efficiency, this model stands out in the residential heating market.

One of the main features of the Bryant 583B is its impressive Annual Fuel Utilization Efficiency (AFUE) rating of up to 95%. This means that the furnace converts up to 95% of the fuel it consumes into usable heat. As a result, homeowners can expect lower energy bills and reduced environmental impact due to decreased carbon emissions.

The Bryant 583B is equipped with a modulating gas valve that allows for precise control of the heating output. This technology enables the furnace to adjust its running capacity based on the heating demands of your home. Instead of operating at a single, high setting, the furnace runs at the required level to maintain the desired temperature, delivering consistent comfort while maximizing efficiency.

Another noteworthy characteristic of the 583B is its two-stage operation. This feature allows the furnace to operate at a lower stage for mild weather, which reduces energy consumption and minimizes noise levels. During colder conditions, it can switch to a high stage for increased heating capacity. This dual approach not only enhances comfort but also prolongs the lifespan of the unit by reducing wear and tear.

In terms of construction, the Bryant 583B is built with durable materials and a robust cabinet, which ensures longevity and resilience over time. It also comes with a quiet operation feature, minimizing disturbances while maintaining a comfortable indoor environment.

The unit is compatible with Bryant's advanced communication technology, enabling seamless integration with smart thermostats. This addition allows homeowners to monitor and control their furnace remotely, optimizing energy usage even further.

In summary, the Bryant 583B furnishes an outstanding combination of efficiency, reliability, and user-friendly technologies. Its modulating gas valve, two-stage operation, and high AFUE rating collectively ensure that customers enjoy a comfortable home environment while significantly reducing energy costs. As energy-conscious choices become increasingly crucial, the Bryant 583B stands ready to meet the challenges of modern heating needs.