Bryant 583B instruction manual Maximum GAS Flow Capacity

Page 10

TABLE 3—PHYSICAL DATA — UNIT 583B — 048090-060130

UNIT SIZE 583B

048090

048115

048130

 

060090

060115

060130

NOMINAL CAPACITY (ton)

4

4

4

 

5

5

5

OPERATING WEIGHT (lb)

421

421

421

 

468

468

468

COMPRESSORS

 

 

 

Scroll

 

 

Quantity

 

 

 

1

 

 

REFRIGERANT (R-410A) Qty (lb)

9.5

9.5

9.5

 

10.0

10.0

10.0

REFRIGERANT METERING DEVICE

.073

.073

.073

 

.086

.086

.086

Orifice ID (in.)Check-Flo-Rater® Piston

 

 

 

 

 

 

 

 

CONDENSER COIL

2/17

2/17

2/17

 

2/17

2/17

2/17

Rows...Fins/in.

 

12.3

12.3

12.3

 

16.4

16.4

16.4

Face Area (sq ft)

 

 

 

 

 

 

 

 

CONDENSER FAN

3300

3300

3300

 

3300

3300

3300

Nominal Cfm

 

22

22

22

 

22

22

22

Diameter (in.)

 

1/4 (1100)

1/4 (1100)

1/4 (1100)

 

1/4 (1100)

1/4 (1100)

1/4 (1100)

Motor Hp (Rpm)

 

 

 

 

 

 

 

 

EVAPORATOR COIL

4/15

4/15

4/15

 

4/15

4/15

4/15

Rows...Fins/in.

 

4.7

4.7

4.7

 

4.7

4.7

4.7

Face Area (sq ft)

 

 

 

 

 

 

 

 

EVAPORATOR BLOWER

1600

1600

1600

 

1750

1750

1750

Nominal Airflow (Cfm)

 

11 x 10

11 x 10

11 x 10

 

11 x 10

11 x 10

11 x 10

Size (in.)

 

3/4

3/4

3/4

 

1.0

1.0

1.0

Motor Hp

 

 

 

 

 

 

 

 

FURNACE SECTION*

 

 

 

 

 

 

 

Burner Orifice No.

3...38

3...33

3...31

 

3...38

3...33

3...31

(Qty...Drill Size) Natural

 

3...46

3...42

3...41

 

3...46

3...42

3...41

Burner Orifice No.

 

 

 

 

 

 

 

 

(Qty...Drill Size) Propane

 

 

 

 

 

 

 

HIGH-PRESSURE SWITCH (psig)

 

 

610 ± 15

 

 

Cutout

 

 

 

 

 

 

420 ± 25

 

 

Reset (Auto.)

 

 

 

 

 

 

 

 

 

 

 

LOSS-OF-CHARGE/LOW-PRESSURE

 

 

20 ± 5

 

 

SWITCH (Liquid Line) (psig)

 

 

 

 

Cutout

 

 

45 ± 10

 

 

Reset (Auto.)

 

 

 

 

 

 

 

RETURN-AIR FILTERS (in.)Throwaway

24 x 30

24 x 30

24 x 30

 

24 x 30

24 x 30

24 x 30

 

 

 

 

 

 

 

 

TABLE 4—MAXIMUM GAS FLOW CAPACITY*

NOMINAL IRON PIPE SIZE (IN.)

INTERNAL DIAMETER (IN.)

 

 

 

 

LENGTH OF PIPE, FT†

 

 

 

 

 

10

20

30

40

50

60

70

80

90

100

125

150

175

200

 

 

1/2

.622

175

120

97

82

73

66

61

57

53

50

44

40

3/4

.824

360

250

200

170

151

138

125

118

110

103

93

84

77

72

1

1.049

680

465

375

320

285

260

240

220

205

195

175

160

145

135

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/4

1.380

1400

950

770

600

580

530

490

460

430

400

360

325

300

280

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1-1/2

1.610

2100

1460

1180

990

900

810

750

690

650

620

550

500

460

430

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Capacity of pipe in cu. ft. of gas per hr. for gas pressure of 0.5 psig or less. Pressure drop of 0.5-in. wg (based on a 0.60 specific gravity gas). Refer to Table C-4, National Fire Protection Association NFPA 54

†This length includes an ordinary number of fittings.

—10—

Image 10
Contents Safety Considerations Rules for Safe Installation and OperationII. Provide Unit Support Receiving and Installation I. Check EquipmentGeneral III. Field Fabricate DuctworkRoof Curb Dimensions Top View RIG and Place Unit Roof Curb DimensionsIV. Provide Clearances VI. Connect Condensate DrainElectrical Unit Weight Unit Height Center of Gravity CharacteristicsRequired Clearance to Combustible Matl Required Clearance for Operation and ServicingNEC. Required Clearances VII. Install Flue Hood Unit 583B Maximum Weight SizeVIII. Install GAS Piping IX. Install Duct ConnectionsInstall Electrical Connections Physical Data Unit 583BMaximum GAS Flow Capacity Nominal Iron Pipe Size Internal Diameter Length of PIPE, FT†HIGH-VOLTAGE Connections Special Procedures For 208-V OperationControl Voltage Connections Electrical Data 583B RLA LRA FLA MCA MocpSTART-UP Start Up Heating Section and Make AdjustmentsPRE-START-UP Check for Refrigerant LeaksInput Heating InputsHeating Number GAS Supply Pressure Manifold Pressure Btuh OrificesError Code LED Indication Heating Temperature Rise F Input BtuhLED Indications Indoor Airflow and Airflow Adjustments Start-Up Cooling Section and Make AdjustmentsSpeed 208/230-3-60 Wiring Diagram 460-3-60 Wiring Diagram Air Filter MaintenanceEvaporator Blower and Motor Cooling Charging Chart, 583B030 Units Blower Housing and Flue Collector Box Flue Gas Passageways WET Coil AIR DELIVERY* Horizontal and Downflow DischargeBurner Ignition Limit SwitchCombustion-Air Blower Main BurnersRefrigerant Circuit Electrical Controls and WiringPressure Switches Evaporator AirflowServicing Systems on Roofs with Synthetic Materials Refrigerant SystemCompressor Oil Liquid Line Filter DrierAIR Conditioner with Puron R-410A-QUICK Reference Guide Troubleshooting Cooling Symptom Cause RemedyTroubleshooting Heating Water in gas line Drain. Install drip legLED TROUBLESHOOTING-ERROR Code LED OFFSTART-UP Checklist Remove and Store in JOB File Preliminary Information
Related manuals
Manual 28 pages 39.19 Kb Manual 30 pages 37.07 Kb

583B specifications

The Bryant 583B is an advanced, high-efficiency gas furnace designed to provide exceptional heating performance and reliability. With a focus on comfort and energy efficiency, this model stands out in the residential heating market.

One of the main features of the Bryant 583B is its impressive Annual Fuel Utilization Efficiency (AFUE) rating of up to 95%. This means that the furnace converts up to 95% of the fuel it consumes into usable heat. As a result, homeowners can expect lower energy bills and reduced environmental impact due to decreased carbon emissions.

The Bryant 583B is equipped with a modulating gas valve that allows for precise control of the heating output. This technology enables the furnace to adjust its running capacity based on the heating demands of your home. Instead of operating at a single, high setting, the furnace runs at the required level to maintain the desired temperature, delivering consistent comfort while maximizing efficiency.

Another noteworthy characteristic of the 583B is its two-stage operation. This feature allows the furnace to operate at a lower stage for mild weather, which reduces energy consumption and minimizes noise levels. During colder conditions, it can switch to a high stage for increased heating capacity. This dual approach not only enhances comfort but also prolongs the lifespan of the unit by reducing wear and tear.

In terms of construction, the Bryant 583B is built with durable materials and a robust cabinet, which ensures longevity and resilience over time. It also comes with a quiet operation feature, minimizing disturbances while maintaining a comfortable indoor environment.

The unit is compatible with Bryant's advanced communication technology, enabling seamless integration with smart thermostats. This addition allows homeowners to monitor and control their furnace remotely, optimizing energy usage even further.

In summary, the Bryant 583B furnishes an outstanding combination of efficiency, reliability, and user-friendly technologies. Its modulating gas valve, two-stage operation, and high AFUE rating collectively ensure that customers enjoy a comfortable home environment while significantly reducing energy costs. As energy-conscious choices become increasingly crucial, the Bryant 583B stands ready to meet the challenges of modern heating needs.