GLW-180H —TROUBLESHOOTING (GENERATOR)
TABLE 8. GENERATOR TROUBLESHOOTING (CONTINUED)
SYMPTOM | POSSIBLE PROBLEM | SOLUTION | |
|
|
| |
| Defective rotor windings? | Check or replace rotor. | |
|
|
| |
Does not decelerate no | Defective solenoid? | Check or replace solenoid. | |
|
| ||
"VOLTAGE OUTPUT". | Defective idle control device? | Check or replace idle control device. | |
| |||
|
|
| |
| Defective solenoid? | Check or replace idle control device. | |
|
|
| |
| Control box wiring malfunction? | Check control box wiring, replace any defective components. | |
Does not decelerate but has |
|
| |
Defective solenoid? | Check or replace solenoid. | ||
"VOLTAGE OUTPUT". | |||
|
| ||
| Idle control device malfunction? | Check or replace idle control device. | |
|
|
|
Practically most welder breakdowns can be prevented by proper handling and maintenance inspections, but in the event of a breakdown, please take a remedial action following the
diagnosis based on the Welder Troubleshooting (Table 9) information shown below . If the problem cannot be remedied, please leave the unit just as it is and consult our company's business office or service plant.
TABLE 9. WELDER TROUBLESHOOTING
SYMPTOM | POSSIBLE PROBLEM | SOLUTION | |
|
|
| |
| Loose or disconnected wires? | Visually check wires, replace if necessary. | |
|
|
| |
| Defective generator? | Check generator, replace if necessary. | |
|
|
| |
No "ARCING" | Poor contactor contact? | Pull the lead wire and check for connection. | |
|
| ||
Defective rectifer Re4 or Re5? | Replace rectifer. | ||
| |||
|
|
| |
| Defective exciter Field Assy? | Replace Field Assy. | |
|
|
| |
| Defective rectifer Re1 or Re2? | Replace rectifer. | |
|
|
| |
| Improper engine speed? | Adjust engine speed. | |
Weak "ARCHING" and low |
|
| |
Improper welding cable? | Use welding cables with sufficient current capacity and length. | ||
outout voltage. | |||
|
| ||
| Improper current control? | Readjust to | |
|
|
|
PAGE 26 —