ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically) Continued
9.Liquid-Line Solenoid Valve (LSV)
An electrically operated shutoff valve to be installed at the outdoor or indoor unit (depending on tubing configuration) and which stops and starts refrigerant liquid flow in response to compressor operation. Maintains a column of refrigerant liquid ready for action at next compressor operation cycle.
NOTE: Compressor Start
SUGGESTED USE: For improved system performance in air conditioners for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. In certain
10.Low-Ambient Controller
Head pressure controller is a cycle control device activated by a temperature sensor mounted on a header tube of the outdoor coil. It is designed to cycle the outdoor fan motor in order to maintain condensing temperature within normal operating limits (approximately100°F/37.8°C high and 60°F/15.5°C low). The control will maintain working head pressure at
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F (12.8°C).
11.Low-Ambient Pressure Switch
A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure
within normal operating limits (approximately 200 psig to 365 psig). The control will maintain working head pressure at
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F (12.8°C).
12.MotorMaster® Control
A fan speed control device activated by a temperature sensor. Designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to
SUGGESTED USE: Cooling operation at outdoor temperatures below 55°F (12.8°C). All commercial installations.
13.Outdoor Air Temperature Sensor
A device that allows the temperature at a remote location (outdoors) to be displayed at the thermostat.
SUGGESTED USE: All Bryant programmable thermostats.
14.Piston Body
This piston body is to be used as a replacement for the FK4C Fan Coil
SUGGESTED USE: All Puron® air conditioner installations matched with FK4C Fan Coils.
15.Support Feet
Four
SUGGESTED USE: For improved sound ratings. Coastal installations.
Windy areas or where debris is normally circulating. Rooftop installations.
16.Thermostatic Expansion Valve (TXV)
A modulating
NOTE: Compressor Start
SUGGESTED USE: For improved system performance in cooling mode for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory. Required for use on all zoning systems.
17.Time-Delay Relay
An SPST delay relay which briefly continues operation of the indoor blower motor to provide additional cooling after the compressor cycles off. SUGGESTED USE: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory.
Required for use on all zoning systems.
18.Winter Start Control
An SPST delay relay which bypasses the
SUGGESTED USE: All air conditioners where
SOUND POWER (dBA)
UNIT |
|
| OCTAVE BAND CENTER FREQUENCY (Hz) |
|
| ||
|
|
|
|
|
|
| |
SIZE | 125 | 250 | 500 | 1000 | 2000 | 4000 | 8000 |
024 | 49.0 | 58.5 | 65.0 | 72.0 | 66.4 | 62.0 | 57.5 |
030 | 49.5 | 62.5 | 68.5 | 72.5 | 67.5 | 62.5 | 56.0 |
|
|
|
|
|
|
|
|
036 | 57.5 | 63.5 | 68.0 | 75.0 | 71.0 | 65.5 | 58.5 |
042 | 54.0 | 67.5 | 68.5 | 72.5 | 71.5 | 64.0 | 60.0 |
048 | 57.0 | 70.5 | 73.5 | 75.5 | 73.0 | 69.5 | 64.0 |
|
|
|
|
|
|
|
|
060 | 70.5 | 72.5 | 72.5 | 75.0 | 69.5 | 65.5 | 61.5 |
Not listed in ARI; however, tested in accordance with ARI Standard
SOUND POWER (dBA)
UNIT SIZE | W/SOUND BLANKET | W/O SOUND BLANKET |
024 | 74 | 76 |
|
|
|
030 | 75 | 77 |
|
|
|
036 | 76 | 79 |
|
|
|
042 | 77 | 79 |
|
|
|
048 | 78 | 80 |
|
|
|
060 | 78 | 80 |