Porter-Cable FN250C, DA250C Assembly, Operation, Maintenance, Service, Accessories

Page 3

Fig. 2

Fig. 3

N

Fig. 4

 

AK

 

 

L

 

 

 

M

 

 

A

 

M

 

A

 

 

 

 

 

O

 

Fig. 5

 

Fig. 6

Fig. 7

G

 

 

F

 

 

 

B

 

P

E

 

 

Fig. 8

 

R

H

 

S

ALWAYS USE SAFETY GLASSES. Everyday eyeglasses are NOT safety glasses. Also use face or dust mask if operation is dusty. ALWAYS WEAR CERTIFIED SAFETY EQUIPMENT:

ANSI Z87.1 eye protection (CAN/CSA Z94.3),

ANSI S12.6 (S3.19) hearing protection,

NIOSH/OSHA respiratory protection.

Before operating this tool, carefully read and understand all instructions in Important Safety Instructions.

ASSEMBLY

Lock off trigger, disconnect air line from tool and remove fasteners from magazine before making adjustments or personal injury may result.

TRIGGER

Keep fingers AWAY from trigger when not driving fasteners to avoid accidental firing. Never carry tool with finger on trigger. In bump action mode (contact actuation mode) tool will fire a fastener if safety is bumped while trigger is depressed.

In accordance with the ANSI Standard SNT-101-2002, the PORTER-CABLE nailers are assembled with a sequential action trigger. For a replacement trigger contact your authorized service center or call 1-888-848-5175.

The red trigger with imprinted on the side, (Cat.# 600852 kit) is the single sequential action trigger and causes the tool to operate in this mode.

The black trigger with imprinted on the side, (Cat.# 600851 kit) is the bump action trigger and permits the tool to be actuated in this manner.

For defining the use of the sequential action trigger and bump action trigger, see the Actuating Tool section of this manual.

Trigger removal (Fig. 2)

1.Lock off trigger.

2.Remove air from the tool.

3.Remove rubber grommet (K) from end of dowel pin (L).

4.Remove dowel pin.

5.Remove trigger assembly from trigger cavity under the handle of the tool housing.

Trigger installation (Fig. 3)

1.Select appropriate trigger assembly to be installed on the tool.

2.Insert the trigger assembly into trigger cavity.

3.Ensure that trigger spring (M) is placed around the trigger valve stem (O).

4.Align the holes of the trigger with the housing holes (N), then insert the dowel pin (L) through the entire assembly as shown.

5.Push the rubber grommet (K) onto the end of the dowel rod as shown.

OPERATION

PREPARING THE TOOL

Read the section titled Important Safety Instructions for Pneumatic Tools at the beginning of this manual. Always wear eye and ear protection when operating this tool. Keep the nailer pointed away from yourself and others. For safe operation, complete the following procedures and checks before each use of the nailer.

NOTE: These nailers are designed to be used without oil.

1.Before you use the nailer, be sure that the compressor tanks have been properly drained.

2.Wear proper eye, hearing and respiratory protection.

3.Remove all fasteners from the magazine.

4.Check for smooth and proper operation of contact trip and pusher assemblies. Do not use tool if either assembly is not functioning properly. NEVER use a tool that has the contact trip restrained in the up position.

5.Check air supply. Ensure that air pressure does not exceed recommended operating limits; 70 to 120 psi, (4.9 to 8.3 bar, 5 to 8.5 kg/cm2).

6.Connect air hose.

7.Check for audible leaks around valves and gaskets. Never use a tool that leaks or has damaged parts.

To reduce the risk of personal injury, disconnect tool from air supply before performing maintenance, clearing a jammed fastener, leaving work area, moving tool to another location or handing the tool to another person.

USING THE LOCK-OFF (FIG. 4)

To reduce the risk of injury, ALWAYS wear proper eye [ANSI Z87.1 (CAN/CSA Z94.3)] and hearing protection [ANSI S12.6 (S3.19)] when operating this tool.

Do not keep trigger depressed when tool is not in use. Keep the lock-off switch rotated to the right (OFF) when the tool is not in use. Serious personal injury may result.

Lock-off trigger, disconnect air line from tool and remove fasteners from magazine before making adjustments. Serious personal injury may result.

Each PORTER-CABLE nailer is equipped with a trigger lock-off switch (A) which when rotated to the right, prevents the tool from actuating. When the switch is centered, the tool will be fully operational. The trigger should always be locked off whenever any adjustments are made or when tool is not in use.

LOADING THE TOOL

Keep the tool pointed away from yourself and others. Serious personal injury may result.

Never load nails with the contact trip or trigger activated. Personal injury may result.

The PORTER-CABLE finish nailers are equipped with load and lock magazines.

Load and Lock Method (Fig. 5)

1.Lock off trigger.

2.Insert fasteners into the rear of the magazine (E).

3.Pull pusher (G) back until the nail follower falls behind the nails.

ACTUATING TOOL

To reduce the risk of injury, ALWAYS wear proper eye [ANSI Z87.1 (CAN/CSA Z94.3)] and hearing protection [ANSI S12.6 (S3.19)] when operating this tool.

The tool can be actuated using one of two modes: single sequential action trigger mode and bump action trigger mode. The trigger installed on the tool as described in the Trigger section of this manual determines the mode of operation.

Sequential Action Trigger - (red)

The sequential action trigger’s intended use is for intermittent nailing where very careful and accurate placement is desired.

To operate the nailer in sequential action mode:

1.Depress the contact trip firmly against the work surface.

2.Depress the trigger.

A nail will fire each time the trigger is depressed as long as the contact trip remains depressed.

Bump Action Trigger - (black)

The bump action trigger’s intended use is for rapid nailing on flat, stationary surfaces. Using the bump action trigger, two methods are available: place actuation and bump actuation.

To operate the tool using the PLACE ACTUATION method:

1.Depress the contact trip against the work surface.

2.Depress the trigger.

To operate the tool using the BUMP ACTUATION method:

1.Depress the trigger.

2.Push the contact trip against the work surface. As long as the trigger is depressed, the tool will fire a nail every time the contact trip is depressed. This allows the user to drive multiple nails in sequence.

Do not keep trigger depressed when tool is not in use. Keep the lock-off switch rotated to the right (OFF) when the tool is not in use.

ADJUSTING DEPTH (FIG. 6)

To reduce risk of serious injury from accidental actuation when attempting to adjust depth, ALWAYS:

Lock OFF trigger.

Disconnect air supply.

Avoid contact with trigger during adjustments.

The depth that the fastener is driven can be adjusted using the depth adjustment next to the trigger of the tool.

1.To drive the nail shallower, rotate the depth setting wheel (F) to the right.

2.To drive a nail deeper, rotate the depth setting wheel (F) to the left.

CLEARING A JAMMED NAIL (FIG. 7)

Lock off trigger, disconnect air line from tool and remove fasteners from magazine before making adjustments or personal injury may result.

If a nail becomes jammed in the nosepiece, keep the tool pointed away from you and follow these instructions to clear:

1.Lock off trigger.

2.Disconnect the tool from air supply.

3.Release pusher from behind nails.

4.Push down front latch (B) then pull up to open front door (R).

5.Remove bent nail, using pliers if necessary.

6.If driver blade is in the down position, insert screwdriver or other rod into nosepiece and push driver blade back in position.

7.Remove rod and close front door.

8.Lift latch to secure door to nosepiece.

9.Reattach air supply.

10.Reinsert nails into magazine (see Loading the Tool).

11.Release pusher.

NOTE: Should nails continue to jam frequently in nosepiece, have tool serviced by an authorized PORTER-CABLE service center.

COLD WEATHER OPERATION

When operating tools at temperatures below freezing:

1.Make sure compressor tanks have been properly drained prior to use.

2.Keep tool as warm as possible prior to use.

3.Make certain all fasteners have been removed from magazine.

4.Lower air pressure to 80 psi or less.

5.Reconnect air and and load nails into magazine.

6.Turn pressure up to operating level (not to exceed 120 psi) and use tool as normal.

7.Always drain the compressor tanks at least once a daily.

HOT WEATHER OPERATION

Tool should operate normally. However, keep tool out of direct sunlight as excessive heat can deteriorate bumpers, o-rings and other rubber parts resulting in increased maintenance.

BELT HOOK (FIG. 8)

The PORTER-CABLE nailers include an integrated belt hook (H) and can be rotated to either side of the tool to accommodate left- or right- handed users. It can also be rotated out of the way when not in use.

If the hook is not desired at all, it can be removed from the tool.

To remove belt hook:

1.Lock off trigger.

2.Disconnect the tool from air supply.

3.Using the appropriate hex wrench, remove the end cap screws from the end cap (S) of the tool.

4.Remove the belt hook.

5.Replace end cap and gasket. Ensure that the three screws are tight.

6.Replace and tighten air fitting.

MAINTENANCE

Lock off trigger, disconnect air line from tool and remove fasteners from magazine before making adjustments or personal injury may result.

DAILY MAINTENANCE CHART

ACTION

WHY

HOW

 

 

 

Drain compressor tanks

Prevents accumulation

Open petcocks or other

and hoses daily.

of moisture in com-

drain valves on compressor

 

pressor and nailer.

tanks. Allow any accumulated

 

 

water to drain from hoses.

 

 

 

Clean magazine, pusher and

Permits smooth opera-

Blow clean with compressor

contact trip mechanism.

tion of magazine, reduces

air. The use of oils, lubricants

 

wear and prevents jams.

periodically or solvents is

 

 

not recommended as they

 

 

tend to attract debris.

Before each use, check

Prevents jams, leaks

Tighten loose screws

to insure all screws,

and premature fail-

or other fasteners using

nuts and fasteners are

ure of tool parts.

the appropriate hex

tight and undamaged.

 

wrench or screwdriver.

 

 

 

CLEANING

Never use solvents or other harsh chemicals for cleaning the non-metallic parts of the tool. These chemicals may weaken the materials used in these parts. Use a cloth dampened only with water and mild soap. Never let any liquid get inside the tool; never immerse any part of the tool into a liquid.

REPAIRS

For assistance with your tool, visit our website at www.deltaportercable.com for a list of service centers, or call the PORTER-CABLE Customer Care Center at (888) 848-5175.

SERVICE

REPLACEMENT PARTS

Use only identical replacement parts. For a parts list or to order parts, visit our website at servicenet.porter-cable.com. You can also order parts from your nearest PORTER-CABLE Factory Service Center or PORTER-CABLE Authorized Warranty Service Center. Or, you can call our Customer Care Center at (888) 848-5175.

SERVICE AND REPAIRS

All quality tools will eventually require servicing and/or replacement of parts. For information about PORTER-CABLE, its factory service centers or authorized warranty service centers, visit our website at www.deltaportercable.com or call our Customer Care Center at (888) 848- 5175. All repairs made by our service centers are fully guaranteed against defective material and workmanship. We cannot guarantee repairs made or attempted by others.

You can also write to us for information at PORTER-CABLE, 4825 Highway 45 North, Jackson, Tennessee 38305 - Attention: Product Service. Be sure to include all of the information shown on the nameplate of your tool (model number, type, serial number, etc.).

ACCESSORIES

Since accessories other than those offered by Porter-Cable have not been tested with this product, use of such accessories could be hazardous. For safest operation, only Porter-Cable recommended accessories should be used with this product.

A complete line of accessories is available from your PORTER-CABLE Factory Service Center or a PORTER-CABLE Authorized Warranty Service Center. Please visit our Web Site www. deltaportercable.com for a catalog or for the name of your nearest supplier.

THREE YEAR LIMITED WARRANTY

PORTER-CABLE will repair, without charge, any defects due to faulty materials or workmanship for three years from the date of purchase. This warranty does not cover part failure due to normal wear or tool abuse. For further detail of warranty coverage and warranty repair information, visit www.deltaportercable.com or call (888) 848-5175. This warranty does not apply to accessories or damage caused where repairs have been made or attempted by others. This warranty gives you specific legal rights and you may have other rights which vary in certain states or provinces.

In addition to the warranty, PORTER-CABLE tools are covered by our:

1 YEAR FREE SERVICE: PORTER-CABLE will maintain the tool and replace worn parts caused by normal use, for free, any time during the first year after purchase.

90 DAY MONEY BACK GUARANTEE: If you are not completely satisfied with the performance of your PORTER-CABLE Power Tool, Laser, or Nailer for any reason, you can return it within 90 days from the date of purchase with a receipt for a full refund – no questions asked.

LATIN AMERICA: This warranty does not apply to products sold in Latin America. For products sold in Latin America, see country specific warranty information contained in the packaging, call the local company or see website for warranty information.

To register your tool for warranty service visit our website at www.deltaportercable.com.

WARNING LABEL REPLACEMENT

If your warning labels (Fig. 9) become illegible or are missing, call (888) 848-5175 for a free replacement.

Français continué

DÉTENTE À ACTION SÉQUENTIELLE

Lorsqu’on utilise la détente par action séquentielle, ne pas actionner l’outil à moins qu’il ne soit fermement appuyé contre la pièce.

RÉGLAGE DE LA PROFONDEUR : pour réduire les risques de blessures graves lors de l’actionnement intempestif de l’outil lorsqu’on tente de régler la profondeur,

TOUJOURS :

verrouiller la détente;

débrancher la source d’alimentation en air;

éviter tout contact avec la détente lors des réglages.

Ne pas enfoncer des clous à l’aveuglette dans les murs, les planchers et autres zones de travail. Des attaches enfoncées dans des fils électriques sous tension, de la plomberie ou d’autres types d’obstacles peuvent entraîner des blessures. (fig. U)

Rester vigilant, faire attention au travail en cours et faire preuve de jugement dans l’utilisation de tout outil électrique. Ne pas utiliser d’outil en cas de fatigue ou sous l’emprise de drogues, d’alcool ou de médicaments. Un simple moment d’inattention en utilisant un outil électrique peut entraîner des blessures corporelles graves.

Les scies, meules, ponceuses, perceuses ou autres outils de construction peuvent produire des poussières contenant des produits chimiques reconnus par l’État californien pour causer cancers, malformations congénitales ou être nocifs au système reproducteur. Parmi ces produits chimiques, on retrouve :

le plomb dans les peintures à base de plomb ;

la silice cristallisée dans les briques et le ciment ou autres articles de maçonnerie ; et

l’arsenic et le chrome dans le bois ayant subi un traitement chimique.

Le risque associé à de telles expositions varie selon la fréquence à laquelle on effectue ces travaux. Pour réduire toute exposition à ces produits : travailler dans un endroit bien aéré, en utilisant du matériel de sécurité homologué tel un masque antipoussières spécialement conçu pour filtrer les particules microscopiques.

Image 3
Contents Pautas DE SEGURIDAD/DEFINICIONES Important Safety Instructions for Pneumatic ToolsDefinitions Safety Guidelines Mesures DE Sécurité DéfinitionsSequential Action Trigger Mode DE Détente Actionnée PAR Coup OU PAR ContactBump or Contact Actuation Trigger To Avoid Double FiresAccessories AssemblyMaintenance ServiceFonctionnement AccessoiresRemplacement Gratuit DE Letiquiette AssemblageServicio EnsamblajeFuncionamiento Mantenimiento’assurer que les clous sont bien introduits dans le nez Troubleshooting GuideGuide DE Dépannage Xxxxxx 16 GA. Finish NailerGuía DE Solución DE Problemas