SECTION 8: SERVICE ADJUSTMENTS
! | Always | disconnect |
power | to the machine | |
before | performing ser- | |
| vice adjustments. Failure | |
| to do this may result in | |
| serious personal injury. |
About Service
This section is designed to help the operator with adjustments that were made at the factory and that might also need to be made during the life of the machine.
This section is provided for your
Similarly, if you are unsure of how to perform any procedure in this section, the Grizzly Service Department will be happy to guide you through the procedures or help in any other way.
Squaring Table
To ensure that the table is square:
1.Disconnect the machine from the power source.
2.Loosen the table tilt knob shown in Figure 17.
Pointer
Table Tilt Knob
Figure 17. Pointer and table tilt knob.
3.Place a square on the table and against the blade as shown in Figure 18.
Figure 18. Check the angle with a square
4.Adjust the table until there is no space between the square and the blade.
5.Tighten the table tilt knob, loosen the pointer shown in Figure 17 and adjust it to 0˚.
G0536 Scroll Saw |