Harbor Freight Tools 97520 operating instructions Clearing Jams

Page 9

Anytime any maintenance or repairs are done (including clearing jams), FIRST:

1.Disconnect the Nailer from its air supply.

2.Empty the Magazine Assembly (70) completely.

3.Attempt to fire the Nailer into a piece of scrap wood to ensure that it is disconected and is incapable of firing any Brads.

CLEARING JAMS

Use eye and ear protection when clearing jams. Always wear ANSI

approved impact safety goggles and appropriate hearing protection.

1.Occasionally, a Brad may become jammed in the firing mechanism of the

Nailer, making the tool inoperable.

2.To remove a jammed Brad, disconnect the Nailer from its air supply.

3.Slide the Pusher (63) back until it locks in place. Then, lean the Nailer back.

4.Remove all Brads from the Magazine Assembly (70).

5.While holding the Pusher (63) in place, press the Release (74) and slide the Pusher forward all the way.

6.Attempt to fire the Nailer into a piece of scrap wood to ensure it is disconnected and is incapable of firing any Brads.

7.With the Driver Guide Cover (52A) facing away from you, push the Locker Spring (92) and remove Driver Guide Cover.

8.Remove the jammed Brad.

9.Close the Driver Guide Cover (52A), making sure it locks in place.

10.Reload the Nailer with Brads. Then, reconnect the air supply hose to the tool.

11.Press the Safety (50A) against a piece of scrap wood, and test fire the Nailer several times while checking for proper operation. If the Nailer is properly firing, you may continue using the tool. If the tool fails to perform properly, immediately discontinue use and have the tool repaired by a qualified service technician.

12.When finished working, disconnect the air supply. Remove the Brads. Then, store the Nailer in a clean, dry, safe location out of reach of children.

SKU 94481

For technical questions, please call 1-800-444-3353

PAGE 9

Image 9
Contents Distributed exclusively by Harbor Freight Tools For technical questions or replacement parts, please callSafety Warnings and Precautions Product SpecificationsRead all instructions before using this tool Save this ManualSKU For technical questions, please call Page Unpacking California Health & Safety Code 25249.5, et seqOperation Testing the Full Sequential Safety Trip MechanismLoading Brads Do not exceed the maximum 120 PSI Operating the NailerClearing Jams INSPECTION, MAINTENANCE, and Cleaning TroubleshootingAnytime any maintenance or repairs are done, First Please Read the Following Carefully Parts ListAssembly Diagram Mission Oaks Blvd. PO Box 6009 Camarillo, CA 93011 800