Global Machinery Company AC40G Pre-start routine, To start & stop the compressor, Air filter

Page 11

Air filter

WARNING. The air filter must be added before first use. Failure to fit the air filter will damage the compressor and will void the warranty.

1. Remove the plastic air

 

2

filter plug from the head of

the compressor.

 

2.To fit the air filter you need to take it apart first. Undo the wing nut, and remove it along with the washer from the air filter.

3.Remove the cover and the air filter.

4.Push out the centre mounting piece and screw this into the air inlet as firmly as possible with your fingers.

4

 

5

 

 

 

5.Replace the air filter holder, then the air filter, cover and washer and wing nut.

Pre-start routine

1.Ensure that the location for the compressor is clean, dry and well ventilated.

2.Ensure the crank case has been filled with oil and is at the correct level, and the air filter has been fitted.

3.Open the regulated output valve (6).

Open the valve by rotating

 

OPEN

the air tap (18) so it is in

 

line with the air outlet

 

(refer to the OPEN picture).

 

To close the valve, rotate the

 

air tap so it is facing to the

 

right or the left side of the

 

air valve (refer to the CLOSED

 

picture).

 

 

4. Start the compressor by

 

CLOSED

following the procedure in

 

the section “To start and

 

stop the compressor”. For

 

the first time of operation,

 

run the compressor for 10

 

minutes with no load and

 

with the outlet valve open

 

to ensure all parts are well

 

lubricated.

 

 

WARNING. Be aware that pressurised air will be discharged from the outlet and care should be taken that this discharge is not directed towards you the operator, or other persons within the area.

To start & stop the compressor

1.Check the rating label on the compressor indicates 230V–240V.

2.Plug in the mains cable of the compressor to a standard 240V household power point and turn on.

3.To start the compressor, lift the On/Off switch (3) on the pressure switch cover (2).

ON

OFF

11

AC30G_AC40G11

12/8/05, 4:49 PM

Image 11
Contents 2HP & 2.5HP Contents Operating Introduction Description of symbolsSpecifications Dear CustomerGeneral safety instructions Additional safety rules for air compressors AC30GAC40G7 12/8/05, 448 PM Contents of carton 114 Know your productUnpacking AssemblyAir filter Pre-start routineTo start & stop the compressor Operation Vibration or abnormal noise TroubleshootingTrouble Possible cause Possible remedy Excessive oil consumption MaintenanceTrouble Possible cause Suggested Remedy Outlet capacityGeneral inspection CleaningPower cord maintenance Save this Manual for future reference